WC300 Advanced Programming
Down Arrow
Set
Figure 33
The WC300 controller is designed to operate by only setting the
time of day and the day of the week. The remaining settings have
been set at the factory. These default settings will work for most
applications.
To change a setting:
Action
Key
Enter basic
SET
programming
Move to desired
UP or DOWN
display
arrows
Enable setting
SET
to be changed
UP or DOWN
Change setting
arrows
Save setting
SET
Return to
REGEN
operation
View history
SET and
values
DOWN
This level of programming is accessible by pressing the SET
button. The UP and DOWN arrows will step through the settings:
Time of day
Day of week
Time of regeneration
Number of days between regeneration (99 day timer)
Day of week regeneration (displays only when number of days
between regeneration equals zero)
(7 day timer)
Amount of regenerant used per regeneration or filter
backwash time
System capacity (view only)
Up Arrow
Regeneration
Duration
Display
Press and
Will show day
release
of week
Will increment
Press and
through the
release
displays
Press and
Display will
release
flash
Value changes
Press and
and continues
release
to flash
Press and
Display stops
release
flashing
Normal
Press and
operation
release
display
Press and
HO will be
hold for 5
displayed
seconds
Accessing History Values
The control features a review level that displays the operation
history of the system. This is a great troubleshooting tool for the
control valve.
To access history values, press and hold SET and DOWN for five
seconds to view the "H" levels.
History Values
Description
H0
Resin volume initial setting value
H1
Days since last regeneration
H2
Current flow rate
H3
Water used today in gallons/m
since Time of Regeneration
H4
Water used since last regeneration
in gallons/m
H5
Total water used since reset in
100s
H6
Total water used since reset in
1,000,000
H7
Average usage for Sunday in
gallons/m
H8
Average usage for Monday in
gallons/m
H9
Average usage for Tuesday in
gallons/m
H10
Average usage for Wednesday in
gallons/m
H11
Average usage for Thursday in
gallons/m
H12
Average usage for Friday in
gallons/m
H13
Average usage for Saturday in
gallons/m
Professional Programming
If a button is not pushed for thirty seconds the controller returns to
normal operation mode. Pushing the UP and DOWN arrows for 5
seconds returns the controller to normal operation.
Any setting that is a time display will not show "AM" for times
between 12:00 midnight and 12:00 noon. "PM" is displayed to
the right of the time for times between 12:00 noon and 12:00
midnight. When using the 24-hour clock, "PM" is not displayed.
In this level all of the programming features of basic programming
are available. In addition, the settings can be locked/unlocked.
24
Range
Cubic feet or liters
0-255
0-47 gpm or 0-177
Lpm
0-65536 gal or
3
0-6553.6 m
0-65536 gal or
3
0-6553.6 m
0-65536 gal or
0-6553.6 m
0-65536 gal or
0-6553.6 m
0-65536 gal or
0-6553.6 m
3
0-65536 gal or
0-6553.6 m
3
0-65536 gal or
0-6553.6 m
3
0-65536 gal or
0-6553.6 m
3
0-65536 gal or
0-6553.6 m
3
0-65536 gal or
0-6553.6 m
3
0-65536 gal or
0-6553.6 m
3
3
3
3
3
3
3
3
3
3
3
3