WC300 Series Initial Power Up

Initial Power Up - (Camshaft proceeds to HOME
position)
• At initial power-up, the camshaft may need to rotate to the
HOME (in-service position).
• Camshaft may take 1 to 2 minutes to return to HOME
position.
• Err 3 will be displayed until the camshaft returns to HOME
position.
• If more than 2 minutes elapses, verify that the motor is
turning the camshaft. If it is not turning, contact Dealer.
Note: The WC300 controller features a self-test sequence. At
first power-up of the control, you may see a number such as
1.00, 1.02, 1.04, or 2.00 displayed. This is an indication that
the self-test is not completed. To complete the test, verify that
the turbine cable is connected. Blow air into the turbine port
(valve outlet) to spin the turbine. The controller will verify that
the turbine works and the self-test will finish. Proceed with the
initial start-up procedure.
SU
MO
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
Figure 22

Initial Startup Step-by-Step Instructions

Step 1: Program System Size
This step may have been performed by your system's OEM
manufacturer. In this case, proceed to step 2.
Note: Capacity is the result of the amount of media in the tank
and the salt setting. The default capacity will be changed by
selecting a different regenerant setting.
• Input system size – media volume – in cubic feet or liters.
• Use UP and DOWN buttons to scroll through resin volume
choices.
• Choose the nearest volume to your actual system size.
• Press SET to accept the system size you've selected.
• If incorrect setting is programmed, see "Resetting the
Control" section below.
TU
WE
TH
FR
SA
DAYS
Note: If the controller was incorrectly set to the wrong system
size, press the DOWN button and SET button for five seconds
to display resin volume in "HO". Press and hold the SET button
for five seconds to reset the controller. Use the UP or DOWN
buttons to increment the display to the correct system size.
Press SET.
SU
MO
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
Step 2: Program Time of Day
• While "12:00" is blinking, set the correct time of day.
• Use the UP and DOWN buttons to scroll to the correct time
of day.
• "PM" is indicated, "AM" is not indicated.
• Press SET to accept the correct time of day and advance to
the next parameter.
SU
MO
TU
Time & Day
Capacity
Hardness
Step 3: Set Day of Week
• Press SET to make the arrow under "SU" flash.
• Use the UP and DOWN buttons to advance the arrow until it
is under the correct day of week.
• Press SET to accept and advance to the next parameter.
SU
MO
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
20
TU
WE
TH
FR
SA
Figure 23
WE
TH
FR
SA
DAYS
Figure 24
TU
WE
TH
FR
SA
Figure 25
DAYS
DAYS

Publicité

Chapitres

Table des Matières
loading

Produits Connexes pour Aerus Origins WC300

Table des Matières