Checking For Leaks
1. Make a leak check solution by mixing 1 part
dishwashing soap with 3 parts water in a
spray bottle.
2. Make sure the control knob on the fireplace is in
the "OFF" position, then connect your fireplace
to the gas supply line and turn the gas on.
3. Spray the leak solution on the valve connections,
paying particular attention to the areas
indicated by arrows in the diagrams.
4. If bubbles appear, shut o
disconnect the hose and inspect all connections
making sure threads are clear of debris.
Reconnect the hose, turn the gas supply on
and retest. If you continue to see bubbles,
turn the gas supply o , disconnect the hose
and call Real Flame Customer Service at
1-800-654-1704 for assistance.
5. If no bubbles appear after 1 minute, wipe
away excess leak solution and proceed to
"Lighting Instructions."
Conversion Plaque
Using wire cutters, remove the plaques that are hanging from the control panel.
Use the included cable kit to string all plaques together including NG conversion
plaque and reattach them to the control panel.
PRE-USE INSTRUCTIONS
the gas supply,
11
Wall