Speedaire Operating Instructions and Parts Manual
Model 1WC94
Troubleshooting Chart (Continued)
Symptom (s)
Possible Causes (s)
Motor will
not run
(Continued)
9. Fuse blown, circuit breaker
tripped
Corrective Actions (s)
9a. Check fuse box for blown fuse and
replace as necessary. Reset circuit
breaker. Do not use a fuse or cir-
cuit breaker with higher rating
than that specified for your partic-
ular branch circuit
b.
Check for proper fuse. You should
use a time delay fuse
c.
Check for low voltage conditions
and/or proper extension cord
d.
Disconnect the other electrical
appliances from circuit or operate
the compressor on its own branch
circuit
21