Pontec PondoFog Notice D'emploi page 9

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
Intended use
PondoFog, referred to as "unit", may only be used as specified in the following:
· For creating light and mist effects.
· For use in water fountain systems and ponds.
· For use above and under water.
· Operate in accordance with instructions.
The following restrictions apply to the unit:
· Operation in swimming pools, bath tubs or water courses which could be used by persons, is forbidden!
· Do not use for commercial or industrial purposes.
· Do not use for long-term operation.
· Never run the unit without water.
· Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.
Installation and connection
5 B, C
Ensure that units are positioned and secured such that they cannot present a hazard:
· Install the transformer at a minimum safety distance of 2 m from the water.
How to proceed:
1. Route the connection cable of the fogger unit through the float unit.
2. Place the fogger unit into the float unit. Ensure that the LEDS point upwards.
3. Connect the plug of the connection cable to the socket on the transformer and hand-tighten the union nut.
4. Place the fogger into the water.
Commissioning/start-up
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
· Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
· Isolate the device (disconnect from the power supply) before carrying out any work on it.
N O T E
The unit will be destroyed if it is operated with a dimmer. It contains sensitive electrical components.
· Do not connect the unit to a dimmable power supply.
Switching on: Insert the power plug of the transformer into the mains socket.
· Check the function of the fogger.
Switching off: Disconnect the transformer power plug.
The operating life of the membrane depends on the operating time, water hardness, water purity etc.
PfG recommends: Do not use the unit for longer than 4 to 6 hours a day.
Remedy of faults
Malfunction
LEDs are not lit.
Luminosity decreasing
No mist generated
S
Cause
Power supply interrupted
Transformer defective
Bulb defective
Lamp glass soiled
Membrane worn
Remedy
Check power supply
Replace transformer
Clean
Replace the membrane.
- EN -