CAUTION
Installation
The Converter must be connected to the single phase net with EARTH CONNECTION, 230V (Single Phase) and 400v (3 Phase) and
50Hz Frequency. The absence of the Earth Connection is very dangerous and will also void the manufacturers Warranty.
Current outlet of the converter to the net is a CETAC type of 50V, 16 Amp, 200 Hz with 2 x Earth connected poles. Connection cable to
the net is single phase and has two more poles with Earth connection. It is complusary that the Connection basis to the net is protected
with a minimum differential of 25 A and with a sensitivity of 300 mA. The absence of this appliance constitutes a serious safety risk and
could also void the manufacturers Warranty.
Location
It is recommended that the converter is positioned as far away from where the vibration process is taking place. It must also be in a dry,
elevated area to avoid contact with water.
Operation
NOTE:- Before connecting the converter to the net, please ensure that the net voltage is approprtiate for the converter. It must be 230V.
The on/off switch has two positions; Position '0' and position '1'. These position have the following functions.
-
Position '0': Stop Position. The switch has to be placed in this position to stop the functioning of the converter.
-
Position '1': On Position. The switch has to be placed in this position to function the converter.
-
Do not start the converter with the pokers switched on.
Recommended Poker Connections
The only pokers that can be connected to the Altrad Belle converters are the models which are manufactured by Altrad Belle.
Altrad Belle is not responsible for the connection of non-recommend pokers which are not mentioned in the Technical Data table.
Connection of other vibrating pokers could be dangerous and will also void the manufacturers Warranty.
The converter doesn't work.
Motor functioning slowly or overheats.
Motor too loud.
The BGF Range is designed so that there is no maintenance required.
If the exterior of the machine becomes dirty due to splashes of concrete, it must be cleaned immediately to stop the concrete from
becoming hardened. Use a wet cloth to remove any residue.
Operating Instructions
Improper operation can be hazardous. Ensure that you are familiar with the operation of the
High Frequency Converter before use.
Trouble Shooting Guide
Maintenance
Check that the pins in the plug are not damaged.
Check that the cable is not broken or damaged.
Check the Capacitor is not damaged.
Check the Thermal Switch for damage.
Check that that the Electric Motor is not overheated.
Clogged ventilation slots. Remove dust.
Device overloaded by pokers.
Check supply voltage.
Damaged bearings.
Rotor is grinding against the stator.
9
GB
GB
GB