Preparations.before.use - Tanita InnerScan BC-581 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
PREPARATIONS BEFORE USE
Inserting the Batteries
Turn the scale over and remove the battery cover by releasing the latch, insert 4 x AA batteries
Open.as.
shown.
(included) with the correct polarity as indicated.
Note: B e sure that the polarity of the batteries is set properly. If the batteries are incorrectly
positioned the fluid may leak and damage floors. If you do not intend to use this unit
Direction.of.
for a long period of time, it is advisable to remove the batteries before storage.
the.batteries.
Please note that the included batteries from the factory may have decreased energy levels over
time.
Positioning the Monitor
Place the measuring platform on a hard, flat surface where there is minimal vibration to ensure
safe and accurate measurement.
Note: T o avoid possible injury, do not step on the edge of the platform.
Handling Tips
This monitor is a precision instrument utilising state-of-the-art technology.
To keep the unit in the best condition, please follow these instructions carefully:
• Do not attempt to disassemble the measuring platform.
• Store the unit horizontally, and place it so that the buttons will not be pressed accidentally.
• Avoid excessive impact or vibration to the unit.
• Place the unit in an area free from direct sunlight, heating equipment, high humidity, or extreme temperature change.
• Never submerge in water. Use alcohol to clean the electrodes and glass cleaner (applied to a cloth first) to keep them shiny; avoid
using soaps.
• Do not step on the platform with wet feet.
• Do not drop any objects onto the platform.
GETTING ACCURATE READINGS
Heels.centered.on.
Toes.may.overhang.
electrodes
measuring.platform
Note: A n accurate reading will not be possible if the soles
of your feet are not clean, or if your knees are bent
or you are in a sitting position.
AUTOMATIC SHUT-DOWN FUNCTION
The automatic shut-down function shuts off the power automatically in the following cases:
• If you interrupt the measurement process. The power will shut down automatically within 10 to 20 seconds,・depending upon the
type of operation.
• If an extreme weight is applied to the platform.
• During programming, if you do not touch any of the buttons within 60 seconds.*
• After you have completed the measuring process.
*Note: If the power shuts off automatically, repeat the steps from "Setting and Storing Personal Data in Memory" (p.3).

To ensure accuracy, readings should be taken without clothing and
under consistent conditions of hydration. If you do not undress,
always remove your socks or stockings, and be sure the soles of
your feet are clean before stepping onto the measuring platform.
Be sure your heels are correctly aligned with the electrodes on the
measuring platform. Don't worry if your feet appear too large for the
unit, accurate readings can still be obtained if your toes overhang
the platform. It is best to take readings at the same time of day. Try to
wait about three hours after rising, eating, or exercising before taking
measurements. While readings taken under other conditions may
not have the same absolute values, they are accurate for determining
the percentage of change as long as the readings are taken in a
consistent manner. To monitor progress, compare weight and body
fat percentage taken under the same conditions over a period of time.
SETTING (RESETTING) TIME
1. Set Hour
Press and hold
for 3 seconds to turn on the unit.
Press
to set hour and then press
.
SET
The unit will beep once to confirm.
2. Set Minute
Press
to set minute and then press
.
SET
The unit will beep twice to confirm the programming.
The unit will then shut down automatically.
• Resetting time
Press and hold
for 3 seconds to turn on the unit. Then follow the procedure 1 and 2.
Note: I f you chose FitPlus mode, please re-input your menstrual period start date.
Select your personal number and enter how many days ago your menstrual period started.
SETTING AND STORING PERSONAL DATA IN MEMORY
You will receive readings only if data has been programmed into one of the personal data memories or the Guest mode.
The monitor can store personal details for up to 5 people.
1. Turn on the Power
Press
to turn on the unit. The unit will beep to confirm activation, the Personal Button
SET
numbers will be displayed, and the display will flash.
Note: I f you make a mistake or want to turn the unit off before you have finished
programming it, press
.
/OFF
2. Select a Personal Key Number
Press
to select a Personal Button. Once you reach the Personal Button number you wish
to use, press
. The unit will beep once to confirm.
SET
3. Set Age
Use
to scroll through the numbers. When you reach your age, press
beep once to confirm.
Continue to the next page.
RECALL MEMORY
SET
/OFF
. The unit will
SET


Publicité

Table des Matières
loading