Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

TRANSMITTING RIDE DATA TO PANOBIKE APP
1
2
On computer
for 6 sec to enter REMOTE
MONITOR MODE.
The computer is ready to
transmit your riding data.
HOW TO INSTALL PANOCOMPUTER
2
Install the
computer
3mm Allen Key
1
Install the bracket on the handlebar
HOW TO RELEASE PANOCOMPUTER
2
Release the
computer
1
Press the lever
DETERMINE WHEEL CIRCUMFERENCE
R
R
Tire Size Designation Wheel Circumference
Tire Size Designation
40-305
16x1.50
1185
47-305
16x1.75
1195
20-571
34-305
16x2.00
1245
23-571
40-355
18x1.50
1340
25-571
47-355
18x1.75
1350
57-584
40-406
20x1.50
1490
60-584
47-406
20x1.75
1515
47-507
24x1.75
1890
20-622
50-507
24x2.00
1925
23-622
40-559
26x1.50
2010
25-622
47-559
26x1.75
2023
28-622
50-559
26x1.95
2050
30-622
54-559
26x2.10
2068
32-622
56-559
26x2.20
2083
35-622
38-622
700x38C
2180
54-622
56-622
29x2.00
2272
57-622
LOW BATTERY
Heart Rate Alarm function. When Heart
limit in Topeak PanoBike App.
* "HEART RATE" Requires optional PanoBike
Heart Rate Monitor.
Please change battery
when this icon shows up.
IMPORTANT NOTE
1.
CLEAR ALL DATA SETTING will clear all stored data.
2.
CLEAR ALL DATA SETTING is required during FIRST SETUP or BATTERY CHANGE.
3.
All data will be cleared when replacing the battery. Before changing battery, write down stored data ODO and ART.
4.
The TOPEAK PANOCOMPUTER can be used in the rain but should not be intentionally submerged underwater.
5.
6.
Do not disassemble the computer body or its accessories.
7.
Check relative positions and gap between sensor and magnet periodically.
8.
Do not use harsh chemicals to clean the computer body or its accessories.
Remember to pay attention to the road while riding.
10.
Check the computer mount before each ride to ensure a secure connection.
11.
Dispose of used batteries according to local regulations.
TROUBLE SHOOTING
1. Is the battery exhausted?
2. Is the battery installed correctly?
1. Is it in setup mode?
speed or
2. Are the relative positions and gap between sensor and magnet correct?
incorrect data
3. Is the wheel circumference correct?
Did you leave the computer in direct sunlight when
not riding the bicycle for a long while?
Is the temperature below -10˚C (14˚F)?
1. Is the chest strap being worn correctly?
heart rate data
2. Is the battery of heart rate monitor exhausted?
PANOCOMPUTER
(Using English version as an example)
On Smart Device, open Topeak PanoBike App and
tap "History" icon
Bluetooth®
DISPLAY
FUNCTION
urren
er
istance
ccumulated istance
Ride ime
ccumulated Ride ime
ow attery ndicator
ace ndicator
Bluetooth®
* "Current Cadence" Requires optional PanoBike Speed & Cadence Sensor.
When this icon is displayed, computer has connected with speed & cadence sensor.
** "Current Heart Rate" Requires optional PanoBike Heart Rate Monitor.
When this icon is displayed, computer has connected with heart rate monitor.
*** When Bluetooth® system icon is displayed, computer is connected or is searching for signal.
O
Wheel Circumference
650C Tubular
1920
650x20C
1938
650x23C
1944
650x25C
1952
27.5x2.25(650B)
2217
27.5x2.35(650B)
2230
700C Tubular
2130
700x20C
2086
700x23C
2096
700x25C
2105
700x28C
2136
700x30C
2146
700x32C
2155
700x35C
2168
29x2.10
2288
29x2.25
2320
MAX HEART RATE ALARM
1. Replace the battery.
2. Make sure that the positive (+) pole of the battery is facing the battery cap.
1. Refer to the data setting procedure and complete the adjustment.
2. Refer to INSTALLATION and re-adjust correctly.
3. Refer to CIRCUMFERENCE SETTING and enter correct value.
Refer to "Clear All Data setting" and initiate the computer again.
Place the computer body in the shade to return to normal state.
The unit will return normal state when the temperature rises.
1. Make sure the position of chest strap is correct.
2. Replace the battery.
WIRELESS
3
Tap "
" to transfer new ride data to Topeak PanoBike App.
SPECIFICATIONS
INCREMENTS
ACCURACY
±
1
%
0.1 km/h or mi/h
±
0.1 %
0.1 km/h or mi/h
0.1 km/h or mi/h
±
0.1 %
0.1 km or m
±
0.1 %
0.1 km or m
±
0.1 %
1 Second
±
0.1 %
1 Minute
±
0.1 %
1 Minute
±
0.003 %
R
rcumference
CHANGING BATTERY
2
Change the
Operation Time
180
battery
up to
hr.
+
-
1
Remove the Battery Cover first
User's Guide

SLEEP MODE

During non-riding
status, if no button
is touched for 10
minutes, the
computer will go into
Sleep Mode. Please
press
to
wake up the
computer.
During non-riding
status, if no
Bluetooth® signal is
connected, the
computer will go into
Sleep Mode after 2
minutes. Please press
to wake up
the computer.
SPECIFICATION
Tech: Bluetooth® Smart (BLE 4.0) super low energy technology
Mount: Handlebar Mount (ø 31.8 mm only)
180 hours (1 hr/ day use) *
Battery: CR2032 x 1 pc (included)
Transmission Range: <5 meter (16.4 ft)
Water resistant: IPX5
Operating temperature: -10°C ~ 50°C (14°F~122°F)
Weight: 30 g / 1.06 oz (computer only)
* Overall battery life is dependent on usage profile and battery condition.
TOPEAK PANOBIKE APP
The ultimate cycling performance app that utilizes
your smartphone's powerful Bluetooth® Smart
capabilities and transforms it into your bike computer,
personal training and health management device.
This app combines the functions of phone, cycle
computer, GPS, music player, camera, and heart rate
monitor (requires purchase of separate PanoBike
Heart Rate Monitor) into one program that allows
you to have loads of fun on your bike ride.
PanoComputer
Syncs with PanoBike
App only.
(Download for Free)
OPTIONAL ACCESSORIES
RideCase Mount RX
Art No. TC1022
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
1) Reorient or relocate the receiving antenna.
2) Increase the separation between the equipment and receiver.
3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
4) Consult the dealer or an experienced radio/ TV technician for help.
user's authority to operate this equipment.
WARRANTY
2-year Warranty: All electronic and mechanical components against manufacturer defects only. Batteries
are not covered under any implied warranty.
Warranty Claim Requirements
To obtain warranty service, you must have your original sales receipt. Items returned without a sales
receipt will assume that the warranty begins on the date of manufacture. All warranties will be void if
the product is damaged due to user crash, abuse, system alteration, modification, or used in any way
not intended as described in this manual.
* The specifications and design are subject to change without notice.
Please contact your Topeak dealer with any questions.
For USA customer service, call: 1-800-250-3068
Website: www.topeak.com
Copyright © Topeak, Inc. 2015
M-TPB-C01-GB 01/15
4
for 6 sec
to return to COMPUTER
MODE.
(Download for Free)
PanoComputer
Mount
Art No. TPB-CM01

Publicité

Table des Matières
loading

Table des Matières