with the arrow pointing towards the flow control, as shown
in the figures.
6. Route supply wires through the flexible conduit fitting into the
wiring chamber of the flow control.
7.
Connect the supply ground wires to the ground lug in the
wiring compartment.
s
NOTICE
!
marked at its terminal using the
8. Connect the supply wires to the screw terminal marked
L and N (Figure 9). Use only copper wires rated for at
least 60 °C. Lead wire terminals should be tightened
to a torque of 4 in-lbs (0.5 Nm).
9. Connect the motor wires to the screw terminal marked
U and V (Figure 9). Use only copper wires rated for at
least 60 °C. Lead wire terminals should be tightened
to a torque of 4 in-lbs (0.5 Nm).
10. Replace the cover and tighten the screws. For proper sealing,
the screws should be tightened to a torque of 13 in-lbs (1.5 Nm).
11. Once the cover has been replaced, ensure that the pump has
been correctly primed and reconnect the main breaker.
Voltage Rating Table
On the product label, verify the voltage rating for the device and do
not exceed that voltage rating.
Supply Voltage
Motor Voltage
Single-phase 115 V
Single-phase 115 V
Single-phase 230 V Single-phase 230 V
Install the cable/conduit connector
The safety earth ground connection is
symbol (Figure 9).
Electrical
Motor Power kW
Diagram
Not more than 0.55
See Figure 9
Not more than 1.1
See Figure 9
NOTE: The components marked out with an X in Figures 7 and 8
are not used for that specific installation.
FOLLOW ARROW DIRECTION
To Controller
Wiring for Liquid-tight Cables
FOLLOW ARROW DIRECTION
To Controller
Wiring for Flexible Conduit

Electrical Diagram

115 VAC 50-60 Hz
230 VAC 50-60 Hz
To 1/2" NPT
Figure 7
Lead Input
Figure 8
L1
N/L2
115 VAC 50-60 Hz
230 VAC 50-60 Hz