SPECIFICATIONS

Description
Name (on label)
Enclosure Rating NEMA
Max. Motor Size
and Voltage
Max. Current
Min. Flow
Electrical Connection FNPT
Plumbing Connection MNPT
Max. Operating Pressure
Max. Operating Temperature
Acceptable Voltage Fluctuation
Frequency
Male Connectors
Protection of Internal Components
Impulse Voltage
Nominal Fluid Temperature
Vertical Installation Only
Figure 3
Inline Flow Control Switch
InlineFLW
Type 4
0.75 hp
0.55 kW
115 V
1.5 hp
1.1 kW
230 V
15 A
0.13 gpm
1/2"
1"
232 psi (16 bar)
131 °F (55 °C)
±10%
60 Hz
NPT 1"
Pollution Degree 2
2.5 kV
68 °F (20 °C)
Figure 4

INSTALLATION: PUMP LOCATION

s
NOTICE
!
Read and follow all instructions.
s
WARNING
!
conduit and fittings must be used to maintain Type 4 rating.
Installation Procedure: Pump
Choose a clean, well-ventilated location that provides protection from
freezing, flooding, and excessive heat. Provide access for service and
draining of the device and pump.
The device can be installed directly on the pump discharge or
between the pump discharge and first water outlet. For proper
operation, Inline Controls must be installed vertically, as indicated by
the text on the product labeling of the control unit. Ensure the flow
direction arrow is facing upwards (Figure 3).
Pump Location
NO
Liquid-tight cables or flexible
Figure 5
5