Instructions and parts manual
PT-STK – Splice and Tee Kit
Compatible with Pr  tecTHERM
This package includes:
• 1 clamp tie
• 1 black cloth tape (6" long)
• 3 cable ties
• 5 mastic strips (1 1/2" long x 1" wide)
• 2 heat-shrinkable caps
• 2 insulated bus wire crimps
• 1 uninsulated braid crimp
• 1 heat-shrinkable tube (8" long x 1" dia.)
• 3 heat-shrinkable tubes (1" long x 1/2" dia.)
• 6 heat-shrinkable tubes (1" long x 1/8" dia.)
• 1 heat-shrinkable tube for ground
E477225 & E477226
Description
The PT-STK kit is suitable for use with Pr  tecTHERM series self-regulating
heating cables to make a splice or tee connection. The kit contains materials
for one splice or one tee connection. This kit does not provide a power
connection: use a PT-PCK or PT-PCS-GF power connection kit for a complete
installation.
Tools required
• Pr  tecTHERM heating cable
• Scissors
• Utility knife
• Cutters
• Flat nose pliers (KNIPEX 2001200)
• Needle nose pliers
• Panduit crimp tools (CT100-A)
• Heat gun
WARNING
• Read this guide and these warnings carefully before
proceeding and always follow instructions.
• Shock and fire hazard: these components are electrical devices
and must be installed correctly for safety reasons.
• Carefully follow all of the installation instructions and read
these important warnings.
• A damaged, frayed or incorrectly installed heating cable can
create electrical arcing and become a fire hazard. In order
to comply with the requirements of the manufacturer, the
National Electrical Codes and Canadian Electrical Codes and
prevent all hazards, a ground-fault protection device must be
used on each heating cable branch circuit.
• Do not damage bus wires during the installation, otherwise
the wires risk overheating and shorting. Bus wires should also
never come in contact or else they will short.
Pr  tecTHERM Instructions and parts manual
products
TM
• All components as well as the ends of the heating cable must
remain dry before and during the installation.
• The black conductive core must be correctly insulated and
kept dry to prevent shorting.
• The installation of this product must be done with the
components supplied. Never use parts or products other than
those listed in this guide.
• When using a heat gun or a torch, always keep the tip moving
to avoid overheating the heat-shrinkable tubes and prevent
damaging the components. Components other than the heat-
shrinkable tubes should never be heated. Heat-damaged
components should be replaced. Fumes created when heating
the heat-shrinkable tubes may cause irritations; take proper
measures to protect yourself.
• The heating cable should not be embedded in the thermal
insulation.
• The cable should not be twisted during installation; the cable's
minimum bending radius is 1.5 in.
• De-energize all power circuits before installation or servicing.
• The tinned copper braid of this heating device must be
connected to a suitable grounding/earthing terminal.
1. Cleanly cut off the end of each cable. Lightly score completely around
and then down outer jacket. The length is 2 3/4 inch.
Do not cut braid or inner jacket.
2. Bend heating cable to break jacket at score then peel off outer jacket.
3. Straighten the braid and twist into a "pigtail".
1

Publicité

loading

Sommaire des Matières pour Flextherm ProtecTHERM PT-STK

  • Page 1 • All components as well as the ends of the heating cable must remain dry before and during the installation. • The black conductive core must be correctly insulated and kept dry to prevent shorting. Instructions and parts manual • The installation of this product must be done with the PT-STK – Splice and Tee Kit components supplied. Never use parts or products other than those listed in this guide. Compatible with Pr  tecTHERM products • When using a heat gun or a torch, always keep the tip moving This package includes: to avoid overheating the heat-shrinkable tubes and prevent • 1 clamp tie damaging the components. Components other than the heat- • 1 black cloth tape (6" long) shrinkable tubes should never be heated. Heat-damaged components should be replaced. Fumes created when heating • 3 cable ties...
  • Page 2 4. At the end of heating cable, lightly score completely around and then 10. Center the 1/2 inch x 1 inch heat-shrinkable tube over the end of down inner jacket. The length is 1 4/5 inch. Do not cut bus wires! heating cable as shown. Heat tube evenly until it shrinks and adhesive flows out both ends. Shrink the tube completely. Immediately after shrinking, pinch with needle nose pliers between wires while tube is still hot. Hold for 10 seconds to ensure seal. 5. Bend heating cable to break jacket at score, then peel off inner jacket. 6. Skive outside edges of black conductive core with utility knife.
  • Page 3 12. Carefully align the heating cable sections and place them together, press 16. Cut off the extra braid. mastic strips firmly together. Fasten with a cable tie at each of the two positions shown. 13. Twist the braid pigtails together. 14. Slide uninsulated crimp over braid to within 1/2 inch from the heating cable. 15. Crimp the braid as shown, using the “CT-100A” crimp tool. Crimp at least twice. 17.
  • Page 4 18. Heat tube evenly until it shrinks and adhesive flows out both ends. Shrink 22. Use insulated bus wire crimps and “CT-100A” crimp tool to crimp each the tube completely. Total heating time should be about 3 minutes. set of bus wires together. 19. Immediately after shrinking, pinch the end of the tube with flat-nose pliers until the end stays sealed, this normally takes 10 seconds. 23. Slide heat-shrinkable cap over each set of bus wires crimps. Heat tube from the end of the heat-shrinkable cap evenly until it shrinks and adhesive flows out. Total heating time should be about 3 minutes. 20. Fold the crimped braid back against the heating cables. Wrap black cloth tape evenly around crimp and heating cables.
  • Page 5 23.1 The adhesive of heat the shrink tube may melt during the shrinking of 24.2 Wrap one strip of mastic with stretched width. the heat-shrinkable cap. 23.2. Pinch again with needle nose pliers as shown. 23.3. Make sure the heat shrink tube is completely sealed between two insulated bus wires and has no visible gap.
  • Page 6: Important

    26. Slide the 8 inch-long heat-shrinkable tube as shown. IMPORTANT Place edge of tube at edge of mastic. While shrinking the tube, make sure you only heat the tube and not the mastic directly, otherwise the mastic will start to bubble. Heat the area of the tube that covers the mastic. The mastic will melt to seal the visible gaps. 27. Shrink the tube completely. Start at the farthest end and work toward the open end. Keep heating after tube has shrunk, to melt adhesive and mastic inside tube. Total heating time should be about 5 minutes (until the melted adhesive and mastic are visible). Caution: To avoid burns allow heated sections to cool before touching! 27.3 Work toward the open end. Shrink the tube completely. 27.1 Start heating at this end. 28. Immediately after shrinking, pinch the end of the tube with flat nose pliers until the end stays sealed; this normally takes 10 seconds.
  • Page 7 For pipe application After the connection has cooled, fold over the connection and fasten it with the third cable tie. For gutter and downspout application • Secure heating cable with downspout hanger (PT-RGCH). • Fasten clamp tie to the center of the connection. • Use a hammer, nail, and clamp tie to secure and keep it off of the gutter bottom. FLEXTHERM Inc. 2400 de la Province, Longueuil, Québec J4G 1G1 Canada Tel. 1 800 353-9843 (Canada) • 1 888 226-2221 (USA) Fax. 1 877 353-98439 client@flextherm.com www.flextherm.com Pr  tecTHERM Instructions and parts manual...
  • Page 8 Manuel d’instructions et de pièces Pr  tecTHERM...
  • Page 9 • L’âme conductrice noire doit être isolée adéquatement et gardée au sec pour prévenir tout court-circuit. • L’installation de ce produit doit être effecutée à l’aide des composantes fournies. Ne jamais utiliser des pièces autres que Manuel d’instructions et de pièces celles énumérées dans ce guide. PT-STK – Ensemble d’épissure / • Lors de l’utilisation d’un pistolet à air chaud ou d’un chalumeau, toujours maintenir la buse en mouvement pour Connection en T ne pas surchauffer les tubes thermorétractables et risquer d’endommager les composantes. Les composantes autres que Compatible avec les produits Pr  tecTHERM les tubes thermorétractables ne doivent jamais être chauffées. Les composantes endommagées par la chauleur doivent être Cet ensemble comprend : remplacées. Des vapeurs pouvant se produire au moment de • 1 attache de bride...
  • Page 10 gaine jusqu’au bout (sur une longueur de 1 4/5 po). 9. Glisser les tubes thermorétractables de 1/8 po x 1 po sur chaque Ne pas couper les conducteurs! conducteur. Pour rétrécir les tubes, déplacer le pistolet à chaleur sans cesse d’un côté à l’autre. Pendant que les tubes se font rétrécir, s’assurer que les tubes restent bien en place. 5. Plier le câble pour briser la gaine à l’incision puis retirer la gaine intérieure. 10. Centrer le tube thermorétractable de 1/2 po x 1 po sur l’extrémité du câble chauffant tel qu’illustré. Chauffer le tube uniformément jusqu’à ce que de l’adhésif s’en échappe des deux extrémités. Rétrécir le tube complètement. Immédiatement après, pincer entre les conducteurs avec une pince pendant que le tube est encore chaud. Tenir 10 secondes pour s’assurer que le tout soit bien scellé. 6. Couper en biseau les parois extérieures de l’âme conductrice avec le couteau tout-usage. Ne pas couper les conducteurs! 7. Extraire les fils exposés de l’âme conductrice. 8. Couper et retirer le reste de l’âme conductrice en préservant les conducteurs dénudés. Ne pas couper les conducteurs! Manuel d’instructions et de pièces Pr  tecTHERM...
  • Page 11 11. Retirer le papier protecteur de la bande de mastic. Envelopper un morceau de mastic autour de la gaine extérieure de chaque câble chauffant et placer tel qu’illustré. 15. Sertir la tresse tel qu’illustré à l’aide d’une pince à sertir CT-100A. Sertir au moins deux fois. 16. Couper l’excédent de tresse. 12. Bien aligner les sections de câble chauffant et comprimer fermement les bandes de mastic ensemble. Fixer le tout avec une attache pour câble à deux endroits, tel qu’illustré. 13. Torsader toutes les tresses ensemble en une spirale. 14. Glisser le connecteur à compression non isolé sur la tresse jusqu’à ce qu’il soit à 1/2 po du câble. Manuel d’instructions et de pièces Pr  tecTHERM...
  • Page 12 20. Replier la tresse sertie contre les câbles chauffants. Envelopper le ruban de tissu noir uniformément et complètement autour de la tresse sertie et des câbles chauffants. 17. Glisser le tube thermorétractable de 1/2 po x 1 po sur le connecteur de compression. 18. Chauffer le tube uniformément jusqu’à ce que l’adhésif s’en échappe des deux extrémités. Rétrécir le tube complètement. Chauffer pendant 21. Sélectionner un fil conducteur de chaque câble et les torsader ensemble. environ 3 minutes. Répéter avec le reste des fils conducteurs. Ne pas torsader ensemble les fils conducteurs d’un même câble chauffant! 19. Immédiatement après, pincer l’extrémité du tube avec une pince plate jusqu’à ce que l’extrémité soit scellée. Tenir 10 secondes pour s’assurer 22. Utiliser des connecteurs à compression isolés pour le sertissage des que le tout soit bien scellé. conducteurs et la pince à sertir CT-100A pour bien sertir les deux regroupements de fils conducteurs torsadés. Manuel d’instructions et de pièces Pr  tecTHERM...
  • Page 13 23. Glisser un embout thermorétractable sur chaque connecteur à 23.3. S’assurer que le tube thermorétractable est complètement scellé entre compression sertis. Chauffer le tube de l’embout thermorétractable les conducteurs isolés et qu’aucune ouverture est visible. uniformément pendant environ 3 minutes jusqu’à ce que l’adhésif s’en échappe. 24. Retirer le papier protecteur de la bande de mastic, envelopper une bande sur la largeur (non la longueur) autour de chaque embout thermorétractable à l’ e xtrémité du tube de ½ po x 1 po et mettre en place. (Important : Étirer les bandes de mastic sans quoi la largeur risque de ne pas être suffisante pour faire le tour complet de l’embout thermorétractable.) 24.1 Étirer les bandes de mastic. 24.2 Envelopper les bandes de mastic étirées.
  • Page 14 25. Bien comprimer les bandes de mastic. 27.2 Chauffer le tube en déplaçant le pistolet d’un côté à l’autre. 26. Glisser un tube thermorétractable de 8 po tel qu’illustré. IMPORTANT Aligner le bout du tube avec le bout de la bande de mastic. Au moment de rétrécir le tube, s’assurer de ne pas chauffer le mastic directement sans quoi celui-ci risque de boursoufler. Chauffer la région du tube qui recouvre le mastic et le mastic fondra pour sceller les ouvertures. 27. Chauffer le tube pour le rétrécir complètement. Commencer à l’extrémité la plus éloignée en vous déplaçant vers l’ouverture. Continuer de chauffer pendant environ 5 minutes après que le tube ait rétréci pour faire fondre l’adhésif et le mastic à l’intérieur du tube (jusqu’à ce que l’adhésif et le mastic fondus soient visibles).Précaution : Pour éviter les 27.3 Chauffer en vous déplaçant vers l’ouverture à l’extrémité. Rétrécir le brûlures, permettre aux sections de refroidir avant de les toucher. tube complètement. 27.1 Commencer à chauffer à cette extrémité. Manuel d’instructions et de pièces Pr  tecTHERM...
  • Page 15 Application pour la protection contre le gel des tuyaux 28. Immédiatement après, pincer l’extrémité du tube avec une pince plate. Tenir 10 secondes pour s’assurer que le tout soit bien scellé. Une fois le raccordement refroidi, replier le raccordement et le fixer à l’aide de la troisième attache pour câble. Application pour dégivrage de toitures et gouttières • Fixer le cable chauffant au support pour descente (PT-RGCH). • Fixer une attache de bride au centre du raccordement. • Utiliser un marteau, un clou ou une attache de bride pour fixer le raccordement et l’empêcher de se rendre au fond de la gouttière. FLEXTHERM Inc. 2400, de la Province, Longueuil, Québec J4G 1G1 Canada Tél. 1 800 353-9843 (Canada) • 1 888 226-2221 (USA) Téléc. 1 877 353-98439 client@flextherm.com www.flextherm.com Manuel d’instructions et de pièces Pr  tecTHERM...
  • Page 16 Manuel d’instructions et de pièces Pr  tecTHERM...