2. DESIGN / SPECIFICATIONS
Primary voltage
Secondary nominal voltage
Secondary maximum voltage
Secondary current
Battery type
Battery capacity
Min.
Impulse S6
40Ah
Impulse S8
60Ah
Protective devices
Input power
Efficiency
Ambient temperature
Protection class
Dimensions cabinet
Safety class
Overall weight
Ambient temperature storage
Relative air humidity max.
3. SAFETY INSTRUCTIONS
Carefully read the manual and the Safety Instructions. Explosion hazard! Avoid
sparking or fire in the immediate environment of the battery.
During charging the battery should be placed in a well vented place.
The IMPULSE S contains parts such as switches and relays that may produce
sparks. If charging takes place in a garage or a similar place then the charger
should be placed in such a position that sparking causes no risk.
Never use the charger in a demounted (open) condition. This may be life
threatening if any parts under voltage are touched!
Note: It is never allowed to attempt to charge batteries that cannot be charged.
Never touch the battery clamps if the charger is in operation.
Never move the charger if it is in operation.
Do not use the charger in combination with a faulty cable or plug or if the charger
itself is damaged. If the mains lead needs replacing this must be done by the
service department of your supplier/dealer.
4
: 230Vac - 50/60Hz - 1-phase
: 24Vdc
: 35Vdc
: can be set by the supplier/dealer max.6A for Impulse
S6, max. 8A for Impulse S8
: Gel
:
Max.
(in order to charge 80% capacity within 8 hours)
60Ah
85Ah
: - protected against reversed polarity
- protected against overvoltage
- protected against high temperatures
: 195W with Impulse S6, 270W with Impulse S8
: min. 80% (at full load)
: 0°C to +40°C
: IP44
: Height 70 x Width 150 x Depth 200mm
: II
: 1.3kg Transport and storage
: -15°C ... +50°C.
: 95% (non-condensing)