Safety Instructions - FEIG Electronic MWD BP Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Quick Reference Guide

8 Safety instructions

This device shall only be used for the purpose intended by the manufacturer.
The operating instructions have to be handed out to each user and accessible at any time.
Improper changes and spare parts resp. special features which are not sold or recommended by the manufac-
turer of the device may cause fires, electric shock and injuries. Such measures therefore lead to nonliability of
the manufacturer and no guarantee will be given.
For this device, the indemnity contract applies in the version valid at the time of purchase. We exclude liabil-
ity for improper or wrong manual or automatic adjustment of parameters resp. improper use of the appliance.
Repair work should only be carried out by the manufacturer.
Connection, initiation, maintenance, measuring and adjustment of the motion detector should only be carried
out by electrical engineers with accident prevention skills.
When handling appliances which get into contact with electric current, VDE-rules have to be observed - espe-
cially VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711, VDE 0860, VDE 0105 as well as the fire – and
accident prevention standard VBG4.
Please switch off current supply prior to opening the device and make sure that it remains off.
If an indicator lamp goes out, this is not a proof that the device is without electricity and disconnected from
power supply. All work that is carried out at the device as well as installation has to be carried out in confor-
mance with the national electric regulations and the local rules.
The user has to make sure that the appliance is mounted and connected according to the technical rules of the
country of installation as well as other regional regulations. This applies especially to cable dimensioning,
protection, earthing, cutoff, disconnection, isolation supervision and excess current cut-out.
Low-voltage operation is not allowed at the relay outputs.
According to machine rule 89/392/EWG, appendix IV, the device may not be used as a safety component. In
facilities with a high danger potential, additional safety devices are necessary !
The hard gold alloy of the relay contacts is destroyed if switching currents of more than 100 mA are used.
Relays with such pre-damaged contacts may only switch currents of more than 100 mA reliably!
If the place of operation is located in direct proximity to foil gates, suitable measures have to be taken to
branch off the electrostatic charging of the gate foil.