Best BHC 62450 BA Mode D'emploi page 16

Table des Matières

Publicité

English
!
the instructions provided.
Warning: Failure to install the screws or fixing device in accordance with
these instructions may result in electrical hazards.
The hood can look different to that illustrated in the drawings in this
booklet. The instructions for use, maintenance and installation, however,
remain the same.
Only for hoods equipped with electronic control:
The 4th speed (intensive) is automatically lowered to 3rd speed after 5
minutes of operation to optimise energy consumption.
- If the hood is left on (lights and/or motor), after 10 hours in the absence
of commands from the user, it will automatically switch to OFF condition
with all services switched off.
- The Buzzer emits a "beep" each time that a command is set from the
keyboard or remote control (optional)
- In the event of interruption of power during the hood, if you restore the
hood in the OFF state, then the engine must be reactivate manually.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard
!
Wear gloves when carrying out installation and maintenance opera-
tions.
AIR VENT
(for ducting versions)
! Prepare the hole and the air vent duct (150 mm diameter).
! Use a duct of the minimum indispensible length.
! Use a duct with as few elbows as possible (maximum elbow angle: 90°).
! Avoid drastic changes in the duct cross-section.
! Use a duct with an as smooth as possible inside.
!
! Do not connect the hood to smoke exhaust ducts for the products of
! For the air vents comply with the provisions laid down by the competent
authorities.
In addition, the air must not be evacuated through a hole in the wall
! Fit air intakes in the room to prevent the hood from creating a negative
pressure in the room (which must not exceed 0.04 mbar); if the hood
is used at the same time as non-electrical equipment (gas-, oil- and
source.
FILTERING OR DUCTING VERSION ?
which type is to be installed.
version (if possible).
Ducting version
duct (diameter 150 mm).
Filtering version
CONTROLS
A) Turns the LIGHTS off
B) Turns the LIGHTS on.
C) Decreases speed down to minimum speed. If pressed for 2" the motor is
turned off.
D) Activates the motor (calling the last speed used) and increases the
speed until reaching maximum.
E) FILTER ALARM/TIMER RESET: when pressing the key during display
key when the motor is running, the TIMER is activated and the hood will
automatically be switched off after 5 minutes.
L1) The 4 green LEDs indicate the running speed.
L2) When the LED is red (motor off) it indicates the FILTER ALARM. When
with the key E.
FILTER ALARM:
After 30h of operation, the LED L2 turns RED. It indicates that the grease
restart the hour counter (RESET) by pressing the key E during display of
CONTROLS
P1) Lights OFF: If pressed, lights go off.
P2) Lights ON: If pressed, lights go on.
P3) OFF/- Motor: Speed drop until minimum speed is reached.
P4) ON/+ Motor: Starts motor and increases motor speed until top speed is
P5) ON/OFF: Switches Sensor off and on( AUTOMATIC or MANUAL
L1) 4 LEDs 4 GREEN LEDs. Indicate set speed
L2) 4 LEDs GREEN indicates AUTOMATIC mode OFF indicates MANUAL
FILTER RESET: shown with Motor Off for 30": After 30h the LED L2
means of P3
SENSITIVITY: In manual mode, by pressing P5 and P4 together, sensitivity
mode is entered. The set sensitivity is indicated by the 4 green LEDs. By
means of buttons P3(-) and P4(+) the desired sensitivity is set.
By pressing P5 the sensitivity can be stored, with return to manual mode.
CONTROLS
Key A: light switch.
Key B:
Key C: second speed switch.
Key D: third speed switch.
CONTROLS
Button A: light button.
Button B: first speed motor ON/OFF button.
Button C: second speed motor ON/OFF button.
Button D: third speed motor ON/OFF button.
, 1 charcoal
E: motor on light.
CONTROLS
Key A: light switch;
- position 0: light off;
- position 1: light on.
Key B: motor switch;
- position 0: motor off;
If pressed for 2", motor switches off.
If pressed for 2" with FILTER RESET on HOUR count reset.
reached
mode).In Automatic mode, LED L2 is on and L1 shows operating speed
In Manual mode, LED L2 is off.
mode RED indicates Filter Reset
A
B
A
C
D
B

Publicité

Table des Matières
loading

Table des Matières