using extension cables outdoors always use a cable
which is marked for outdoor use.
▪ It is very important that the compressor is positioned
so that there is an adequate airflow around the
machine. The compressor should be situated so that it
has 50 cm of obstacle free space around its air
receiver (tank) and pump/motor unit.
▪ For the correct function and longevity of your air
compressor it is important that the air, which is
drawn into the compressor is clean. The compressor
should not be used in an area, where the air is
contaminated with dust.
▪ Ensure that the compressor is placed on ground,
which is flat and does not have an incline greater than
15 º. If the compressor is placed at an angle greater
than 15 º in any direction, damage to the pump unit
will result.
▪ Operating the compressor without the air filter will
cause severe damage to the pump unit.
INSTALACIÓN
1. The machine should be operated in the room with
temperature of 5-40 ºC and relative humidity of
greater that 80%. Surrounding area of the machine
should be clean, dry, free of corrosive gas, well
ventilated and not direct sunlight.
Note: Special power line for the machine is
recommended with short circuit protection and reliable
grounding device.
2. After unpacking check the machine for any missing
parts and damages, check accessories and spare parts
and technical document supplied together with the
machine.
3. Connection of air pipes: connect air supply pipe with
the quick coupling.
4. Check if switch is "OFF".
5. Electrical connection: check if
power supply is normal. Insert
the plug for the machine into
power supply socket.
Installation of the machine is
completed.
6. Remove the plug closing the air
inlet and place the filter in that
hole (using the compressor
without the filter could
seriously damage the motor).
TEST RUN OF THE MACHINE
1. Close drain valve and air supply value. Check if the
reading of pressure gauge is below 6 bar. Turn the
operation switch to "ON", the machine will start
immediately. The reading of pressure gauge will
slowly rise with increasing pressure inside the air
tank. When the reading of pressure gauge reaches 8
bar, pressure switch activates, the power supper is
cut off, machine stops running.
2. During the period when the machine stops running
observe if the reading of pressure meter is
decreasing. If there is no leakage of air in the
machine, open air supply valve to begin supply of
compressed air. When the pressure in the air tank
decreases to 6 bar, pressure switch resets and power
supply resumes, the machine starts running again.
The pressure in air tank increases again. If the
machine can automatically stop and start, the
machine works normally.
3. Turn the operation handle for pressure switch to
"off" position (Switch off position), then pull out the
plug of the machine. Test run is completed.
OPERATION
1. To operate ther compressor correctly and safely read
carefully this operation instruction.
2. Insert the plug of the machine in power socket of 230
V, 50/60 Hz. Open ball valve, turn the operation
handle for pressure switch to "ON" position, the
machine will run in a normal condition.
CLEANING
▪ Clean the items with a soft brush or a wiper
moistened with a suitable biodegradable solvent.
▪ Do not use inflammable liquids like petrol or alcohol,
they are a fire risk and will damage the finish and
plastic parts.
▪ Ensure that the cooling fins on the pump body are
kept clean. Fins heavy with dust have poor cooling
properties and the compressor will over heat and
damage will occur.
FAULTS
▪ Have the air compressor repaired by a competent
person.
▪ Use only genuine replacement parts, which are
available from the authorized dealer or distributor.
▪ Do not use modified or non-genuine parts.
▪ Do not use the air compressor with damaged parts,
before further use a damaged air compressor must be
carefully checked by a qualified person to determine
that it will operate properly. Check for breakage of
parts, mountings and other conditions that may
affect its operation. An authorised service centre
should properly repair a damaged part, unless
indicated otherwise in the instruction manual.
TRANSPORTATION AND
STORAGE
The machine should be transported and stored in
following condition:
▪ Ambient temperature: -40 ºC ~ 55 ºC
▪ Relative humidity: 80 %
▪ Atmosphere pressure: 500 Hpa-1060 Hpa
MAINTENANCE
▪ Maintain air compressor with care
▪ Keep the air compressor clean for better and safer
performance.
▪ Follow instructions for changing accessories.
▪ Inspect the air compressor and extensions
cables/hoses occasionally; have them repaired
by a qualified person or authorised service body.