Every 40 minutes, the dryer solenoid valve activates to
release air and water.
Draining of air tank
The frequency for draining is depend on environment
condition and operation time, but usually once every 2-3
days. The way to drain off the condensate is as follows:
Put the drain pipe connecting drain valve quick coupling
in a container. With compressed air in the air tank,
slowly turn counter-clockwise the knob on the drain
valve to drain off the water in the air tank until all
accumulated water comes out from the pipe. After that
turn tightly clockwise the knob to ensure no leakage.

TECHNICAL SPECIFICATION

Voltage:
Power:
Aspirated air:
Effective airflow (4 bares):
R.p.m.:
Noise:
Pressure:
Tank capacity:
Weight:
Height:
Width:
Depth:

ELECTRICAL CIRCUIT

AIR PASSAGE DRAWING

R-110300 / R-110310
230 V, 50/60 Hz
850 W
152 l/min
80 l/min
1400
53 dB
6-8 bar
38 L
30 / 37 kg
650 mm
390 mm
390 / 540 mm
Change of filter
An air filter is installed on air inlet of the air compressor
to prevent the dust in the air from entering the air
compressor and reduces noise. After used for a period of
time the filter core in the air filter will get clogged. In a
result sucking capacity of the air compressor will be
reduced, therefore the filter core must be replaced
regularly. The way of replace is as follows: open the lid
on the air filter, take out the old filter core, put in a new
one, and then close the lid.
R-110330 / R-110340
230 V, 50/60 Hz
1600 W
230 l/min
160 l/min
1400
54 dB
6-8 bar
60 L
58 / 66 kg
750 mm
680 mm
370 / 480 mm