2A3 – MODELS WITH GRAVITY DRAINAGE
N.B.
The drainage line must comprise of a sump
pit, free flow, of proper size capable to
dispose twice the water flow indicated on
the data diagram. It must be close to the
drain
pipe
of
the
bending, stretching or jointing the pipe.
-
Drain line must reach sump pit with free
flow without constraints, stretching, bends,
kinks, or being forced.
-
Connect the waste outlet pipe to the main
drain pipe, fitting a trap, or place the
outlet pipe over an "S" trap set into the
floor.
2A4 – MODELS WITH DRAIN PUMP
-
Position the outlet pipe at a height
anywhere between 30" and 40" from the
floor. (Fig.6)
Fig. 6
2B - ELECTRICAL CONNECTION
N.B.
All contacts must be mechanically open,
ground
line
included,
between contacts 3 mm, with magnetic
overload or fuses, calibrated for a max,
sustained
current
in
machine date plate. It must be installed
outside the machine but close to it. It must
feed only one machine at time.
Machine cannot be connected to mains
using adapters, plug, cables or cable
extensions
not
properly
adequate
to
the
machine's
requirements.
- Verify main specifications comply with
indicated requirements on the data plate
located on the front bottom panel of the
machine (par. ID/RATING/DATA PLATE), that
exists for the connection, a main breaker
with proper size suitable for the machine
and a proper ground system.
machine
without
min.
distance
agreement
with
sized
and
power
WARNING!
THE
MANUFACTURER
RESPONSIBLE FOR DAMAGES OR INJURIES
CAUSED FOR IMPROPER GROUNDING. THE
GROUND
AND
THE
CONNECTIONS
SHOULD
COMPLIANCE
WITH
REGULATIONS.
The line cable should be replaced with a spare
cable supplied by the manufacturer. For
replacement indicate machine type, machine
serial number and possible modifications of
the installation. Power cable cannot be
stretched or kinked during normal operation.
Grounding point on machine must be
connected to nearest appliance terminal
according to Safety Standards.
2C
WARNING
DISPLAYED
ON
THE
PANEL
N.B.
If the machine is in OFF mode, warning
messages are not displayed. Turn ON the
machine to visualize the type of warning
message on the appliance.
Following warning messages on the display
are provided:
ALR1 - WATER FILL
Water fill not completed during the available
maximum time (10min).
Verify
that
water
supply
connected, opened and free of obstructions.
Verify that solenoid valve filter is free of
possible obstructions and deposit.
Verify that water supply pressure is adequate
(par.1D – Technical Data).
Verify that machine's door is completely
closed and the overflow device is correctly
positioned inside the tank.
N.B.
If water fill timing expires the solenoid
valve is automatically interrupted. To
restart solenoid valve press any button on
the control panel.
ALR2 - DRAIN ANOMALY
Drainage not completed on the maximum
programmed timing.
IS
NOT
ELECTRICAL
BE
IN
NATIONAL
MESSAGES
CONTROL
is