Safety Information and Maintenance
(Part of the Operating Instructions for Safety Switch CET-AR/CET-AP)
Inspection and service
Warning! Loss of the safety function because of
damage to the system.
In case of damage, the related component must
be replaced completely.
Only accessories or spare parts that can be ordered
from EUCHNER may be replaced.
Regular inspection of the following is necessary to
ensure trouble-free long-term operation:
Check the switching function
f
Check the secure fastening of the devices and
f
the connections
Check for soiling
f
Check the safe function of the safety guard par-
ticularly
after any setup work
f
after the replacement of a CET component
f
after an extended period without use
f
after every fault
f
No servicing is required, repairs to the device are
only allowed to be made by the manufacturer.
EUCHNER GmbH + Co. KG Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen Tel. +49 711 7597-0 Fax +49 711 753316 info@euchner.de www.euchner.com
Technical data (extract)
Parameter
Value
Material
- Slide
Stainless steel
- Safety switch housing
Die-cast aluminum
Mechanical life
1 x 10
operating cycles
6
Ambient temperature
-20 .... +55 °C
at U
= DC 24 V
B
Locking force F
6500 N
max.
Locking force F
F
Zh
in accordance with
F
=
max
1,3
Zh
test principles GS-ET-19
Connection
2 plug connectors M12,
5- and 8-pin
or 1 plug connector RC 18
Operating voltage U
B
(reverse polarity protected,
DC 24 V ±15%
regulated, residual ripple
< 5 %)
Current consumption I
80 mA
B
Max. switching delay from
400 ms
state change
Max. difference time between
10 ms
the two safety outputs
Safety outputs OA/OB
Semiconductor outputs, p-
switching, short circuit-proof
Output voltage U(OA)/U(OB)
1)
HIGH
U
/ U
U
-1.5 V ... U
(OA)
(OB)
B
LOW
U
/U
0 ... 1 V DC
(OA)
(OB)
Switching current
1 ... 200 mA
per safety output
Utilization category
DC-13 24 V 200 mA
according to
Caution: outputs must be
EN IEC 60947-5-2
protected with a free-wheeling
diode in case of inductive
loads.
Performance Level
in accordance with
PL e
EN 13849-1
Classification
PDF-M
acc. to EN IEC 60947-5-3
Switching frequency
0.5 Hz
Solenoid
Solenoid operating voltage U
CM
(reverse polarity protected,
DC 24 V +10%/-15%
regulated, residual ripple
< 5 %)
Current consumption
480 mA
solenoid I
CM
Power consumption
10 W
Duty cycle
100 %
Reliability values
Head downward
according to EN ISO
or horizontal
13849-1
Category
4
Performance Level (PL)
e
PFH
3.1 x 10
/ h
-9
d
Mission time (years)
20
= 5000 N
B
Head upward
3
e
4.29 x 10
/ h
-8
20