5.8
Also approved for
Respirator Helmet is a leather outer cape (BAC-
BH-PB-0024). The leather cape is of heavier
construction than the standard nylon cape, and
is recommended for blasting applications where
metallic abrasives are being used, and/or
operating in confined spaces where the cape will
be subjected to more aggressive rebounding of
the abrasive.
5.9
The leather cape is fitted in the same manner as
the standard nylon cape.
5.10
Fit
the
Air
Flow
Controller/Climate Controller belt around the
waist and adjust for a firm fit as required. It may
be necessary for another person to assist the
operator with fitting of the helmet and belt
assembly.
6.0
OPERATING ADJUSTMENTS
6.1
The alternate Air Flow Controller (BAC-AF-PB-
0036) allows the operator to increase or
decrease the volume of air entering the helmet
by turning the regulator adjusting ring.
6.2
Refer to Operating Manual ZVP-PC-0039-01 for
further details on the operation of the Air Flow
Controller.
6.3
The alternate Air Cooling Controller (BAC-AF-PB-
0032)
allows
the
temperature of the incoming air supply to the
helmet. This is done by rotating the adjusting
knob until the desired air temperature is
achieved.
use
with the
Titan
II
Controller/Air
Cooling
operator
to
adjust
the
- 5 -
6.4
It
is
recommended
Controller be used when the incoming air supply
to the respirator helmet becomes too warm for
the operator to work comfortably.
6.5
It is normal for warm air to be discharged from
the vent hole in the bottom of the Air Cooling
Controller while in operation.
6.6
Refer to Operating Manual ZVP-PC-0042-01 for
further details on the operation of the Air
Cooling Controller.
6.7
The alternate Climate Controller (BAC-AF-PB-
0175) operates in a similar manner to the Air
Cooling Controller, but may be used to supply
either heated or cooled air to the respirator
helmet. The Climate Controller can be switched
from heating to cooling by way of the control
switch located on the top of the unit.
6.8
It is recommended that the Climate Controller
be used when the incoming air supply to the
respirator helmet becomes too warm or too cool
for the operator to work comfortably.
6.9
Refer to Operating Manual ZVP-PC-0043-01 for
further details on the operation of the Climate
Controller.
7.0
REMOVAL AND STORAGE INSTRUCTIONS
7.1
Prior
to
removing
disconnect the outer cape retaining clips, then
carefully
lift
the
Disconnect the air supply to the respirator
helmet when not in use. It is also recommended
to turn off the compressed air supply to the
respirator airline filter.
7.2
When not in use, it is recommended that the
respirator helmet be suspended from the eyelet
in the strap handle provided in a clean and dry
area, in order to prevent dust and abrasive from
that
the
Air
Cooling
HEAT/COOL
the
respirator
helmet,
respirator
helmet
off.