Jandy
Pro Series VS FloPro™ Series Variable-Speed Pump
®
6.
Slide dip switches 1 and 2 up, so they are in the ON
position, and slide switches 3 and 4 down, so they
are in the OFF position. See Figure 9.
Controller
(Rear View)
4-Position
DIP Switch
5-Position
DIP Switch
Figure 9.
Wiring Variable-Speed Controller (JEP-R)
7.
Connect the other end of the cable to the controller.
Match the colors of the wires with the appropriate
connector positions as follows: 1- red, 2- black, 3-
yellow, and 4- green.
8.
Restore power to the pump and verify the operation
of the controller.
9.
Refer to the Variable-Speed Controller Owner's
Manual, H0412200, to operate the pump.
|
5 4 3 2 1
4 3 2 1
RS485
REMOTE CONTROL
Variable-Speed
Pump
Power Wiring
Port
Product may differ from images shown
Installation & Operation Manual
Remove to
access
DIP switch
Figure 10. DIP Switch access cover on VS-FHP1.0 &
VSFHP165JEP Motor
3.3
VS FloPro Pump Dip Switch Settings
The 4- or 5-position dip switch is located at the rear of
the VS FloPro pump. This dip switch serves two (2)
functions: it selects the pump address, and it determines
what type of controller will be used with the pump.
Table 4.
VS-FHP1.0, VSFHP165AUT &
VSFHP165JEP Dip Switch Settings
Switch
Switch
1
2
OFF
OFF
ON
ON
Switch
Switch
3
4
ON
OFF
OFF
ON
ON
ON
Table 5.
VS-FHP2.0, VSFHP270AUT &
VSFHP270JEP Dip Switch Settings
Switch
Switch
1
2
OFF
OFF
ON
ON
Switch
Switch
3
4
ON
OFF
OFF
ON
ON
ON
ENGLISH
Switch
Controller
5
ON
AquaLink RS, AquaLink
PDA, or AquaLink Z4™
ON
Variable Speed Controller
Pump Address
PUMP 2
PUMP 3
PUMP 4
Controller
®
AquaLink
RS, AquaLink PDA, or
AquaLink Z4
Variable Speed Controller
Pump Address
PUMP 2
PUMP 3
PUMP 4
Page 13