5
Replacement Parts
A. Convection Blower Replacement
1. Turn the dial control to the off position. Unplug the
power to the unit.
2. The convection blower is located in the rear of the unit.
3. Using #2 Phillips screwdriver, loosen the bolts on the
rear of the unit holding on the side panels. You do not
need to remove the screws. Remove side panels by
lifting up and out.
4. Unplug the wires from the convection blower motor
from the right side of the unit.
5. Remove the two screws holding the convection
blower housing to the sheet metal plenum. Using a
slight twisting motion, rotate the blower back and it
will release.
Loosen Screws,
Do Not Remove
customerservice@ghpgroupinc.com
B. Exhaust Blower Replacement
1. Turn the dial control to the off position. Unplug the
power to the unit.
2. Remove the left side panel by loosening the two or
three bolts in the rear of the unit.
3. Disconnect 2 white wires from the white and blue wires
of the exhaust blower.
4. Remove the blower motor attached to a removable
plate on the exhaust blower. Depending on the model,
use a 1/4 inch socket, or 1/4 inch Nut Driver or #2
Phillips Head screw driver to loosen the 6 screws in the
keyhole shaped holes and rotate the plate. It is only
necessary to loosen screws.
5. Remove the exhaust blower and gasket.
6. Check for degradation on the gasket and replace if
necessary using the gasket included in the kit.
7. Re-install in reverse order.
7077-801D • September 17, 2019
19