LED color scheme
Bandwidth accuracy (standard mode)
Bandwidth accuracy (excavator mode)
Automatic power-off
Weight (casing)
Dimensions (L x W x H)
Built-in securing screw
Operating temperature range
Storage temperature
Air humidity
Protection class
Battery
Power source
Charging temperature
Battery charging time
PRA 85 mains adapter
AC supply
AC frequency
Rated power
Rated voltage
Operating temperature range
Storage temperature range (dry)
Weight
Dimensions (L x B x H)

5 Safety instructions

5.1 Basic information concerning safety
In addition to the information relevant to safety given
in each of the sections of these operating instructions,
the following points must be strictly observed at all
times.
5.2 General safety rules
a) Keep other persons, especially children, away
from the area in which the work is being carried
out.
b) Check the condition of the tool before use. If the
tool is found to be damaged, have it repaired at a
Hilti service center.
Upper arrow (red)
Pre-set level line (green)
Lower arrow (red)
Fine bandwidth = 5 mm (³/₁₆ in)
Standard bandwidth = 10 mm (³/₈ in)
Coarse bandwidth = 20 mm (³/₄ in)
Fine bandwidth = 12 mm (¹/₂ in)
Standard bandwidth = 25 mm (1 in)
Coarse bandwidth = 50 mm (2 in)
After 30 minutes in switched-on mode when no laser
beam is received
1.2 kg (2.5 lbs)
241 mm x 111 mm x 106 mm (9.5" x 4.38" x 4.2")
Can be secured to the tubular section of the magnetic
holder (max. 1" outside diameter)
-20...+60°C (-4 °F to 140 °F)
-40...+70°C (-40 °F to 158 °F)
90% air humidity for 48 hours at 32 °C
IP 67
5 AA NiMH (cannot be replaced on the construction
site)
Continuous indication in the laser beam: 25 hours
(when battery is fully charged and at 70 °F)
+5...+35°C (41 °F to 95 °F)
5 hours for full charge
115...230 V
47...63 Hz
40 W
12 V
+0...+40°C (32°F to +104°F)
-25...+60°C (-13°F to 140°F)
0.23 kg (0.51 lbs)
110 mm x 50 mm x 32 mm (4.3" x 2" x 1.3")
c) Do not render safety devices ineffective and do
not remove information and warning notices.
d) The tool must be checked at a Hilti service center
after it has been dropped or subjected to other
mechanical stresses.
e) If using the magnetic holder, check that the tool
is fitted correctly.
To avoid measurement errors, the receiving area
f)
must be kept clean.
g) Although the tool is designed for the tough condi-
tions of jobsite use, as with other optical and elec-
tronic instruments (e.g. binoculars, spectacles,
cameras) it should be treated with care.