Napoleon Alluravision Série Manuel D'installation Et D'utilisation page 19

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.3
240V hard wiring installation (NEFL42/50/60/74/100CHD-1 only)
A
1. Remove the securing screws from the junction box
cover plate, located on the left side, at the back
of the appliance. Discard the original junction box
cover plate and set screws aside.
2. Loosen the securing screws in the terminal block to
A
remove the power cord.
3. Install the strain relief to the junction box cover plate
(supplied), and feed the supply wires through the
7/8" (22mm) hole. Use minimum 14AWG/3.
4. Insert Green or bare copper wire to the designated
G Terminal. Tighten the screw.
5. Insert White wire to the designated N Terminal. Tighten the screw.
6. Insert Black wire to the designated L1 Terminal. Tighten the screw.
7. Insert Red wire to the designated L2 Terminal. Tighten the screw.
8. Make sure all connections are tightened properly.
9. Reinstall the junction box cover plate using the screws removed in step 1.
MATERIAL: CLASS IIIA-2 PERMANENT LEXAN ADHESIVE LABEL, MINIMUM THICKNESS 0.1MM, NON WATER SOLUB
electrical information
(N)
WHITE (N)
HARDWIRING DIAGRAM
(L1)
BLACK (L1)
SCHÉMA DE BRANCHMENT
(L2)
RED (L2)
(G)
PAR CÂBLE
GREEN (G)
120V
WHITE/BLANC (N)
BLACK/NOIR (L1)
RED/ROUGE (L2)
GREEN/VERT (G)
240V
WHITE/BLANC (N)
BLACK/NOIR (L1)
RED/ROUGE (L2)
GREEN/VERT (G)
WHITE/BLANC (N)
BLACK/NOIR (L1)
GREEN/VERT (G)
WHITE/BLANC (N)
BLACK/NOIR (L1)
RED/ROUGE (L2)
GREEN/VERT (G)
W385-2464 / A
19
W415-2841 / F / 05.10.22