1) SHORTING OUT OF DEFECTIVE COMPONENTS
This is a very common problem which saves short term expense at the risk of a large future cost.
Any heaters found in this condition should be removed immediately.
2) IMPROPER ENCLOSURES
When heaters are installed partially to the outside for fresh air intake, strict adherence must be
made to the minimum clearance to combustibles given on the instruction plate. Wood framing
around a heater can cause a safety hazard.
3) SUPPLYING LIQUID PROPANE TO HEATER NOT EQUIPPED WITH A BUILT IN VAPORIZER
This problem has occurred upon initial start-up. To minimize the damage, shut off the gas
supply and let the heater run until all of the liquid in the lines had been consumed.
1) Set the gas selector valve for fuel being used. Confirm incoming supply gas pressure.
2) Open manual shut-off valve on heater.
3) Connect power supply (120 volt). Check with a voltmeter to confirm full voltage.
4) SLOWLY open shut-off valve at gas meter or propane tank. Check for leaks, bleed air from supply
hose at heater.
5) Push up the "ON" switch.
6) Set thermostat for desired room temperature.
7) To stop, turn thermostat down or push down the stop switch.
(Burner will turn off; after 5 seconds fan will turn off.)
8) Close manual shut-off valve on heater.
NOTE: "FAN ONLY" switch must be in the Off position for Heat Mode.
NOTE: If the heater will be shut down over night, close valve at fuel supply first and burn all gas
out of line.
The appliance area should be kept clear and free from combustible materials, gasoline, and other
flammable vapors and liquids.
Ensure that the flow of supply air and combustion gases is not obstructed.
The installation and operation of the heater shall comply with the code requirements specified by
the authorities having jurisdiction.
General criteria for the use of construction heaters may be found in the applicable sections of
American National Standard A-10.10-1987, Safety Requirements for Temporary and Portable Space
Heating Devises and Equipment Used in the construction industry.
THE INSTALLATION AND MAINTENANCE OF THE HEATER MUST BE ACCOMPLISHED BY A
QUALIFIED SERVICE PERSON.
8