Installation
3. Connect the AC output wiring to the
inverter AC output hard-wire (pigtails
leads) by using wire connectors. Black to
black, white to white. (Fig. 5)
Fig. 5
AC Output Wiring
Line (L)
Black
Neutral (N)
White
Green or
Ground
Bare copper
4. Double check all connections to make
sure the wires are in correct position and
all wires are secured.
5. Wrap the wires and place into the
compartment. Replace the cover to
the inverter and secure with the screw
provided. (Fig. 6)
Fig. 6
Wire Length/
Gauge
Within 25 feet /
AWG# 14~16
6. Replace the wire clip and fix with 2 screws
provided. (Fig. 7)
Fig. 7
7. Using a 5/32" hex wrench, loosen the
ground lug screw located on the mid left
side of the rear panel. Insert an 8AWG
copper wire from this lug to chassis
ground. Tighten the lug securely with
35inch-lbs torque maximum. (Fig. 8)
8AWG
Fig. 8
Ground wire
Ground lug