Troubleshooting - Furrion net-zero FIVBDP10A Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting

TROUBLE/SYMPTOM
No AC output
(Red LED lit, Yellow LED
not lit)
No AC output
(Red & Green LED not lit)
Appliance won't start
Refrigerator won't start
13
POSSIBLE CAUSES
Low battery voltage
Over battery voltage
Output short circuit protection
Inverter shut down by overload
Inverter overheat thermal
shutdown
DC cable loosen or Inverter fuses
open
Excessive start-up load
Excessive start-up load
The battery cable or the output
wiring cable are not the correct
size
The cold cranking amperage
of the battery is lower than
the starting load amperage
requirement
SOLUTION
Recharge or replace battery
Check the battery voltage
Check the output, remove the short
circuit and restart the inverter by
turning the switch off/on
Remove or reduce load, restart the
inverter by turning the switch off/on
Remove or reduce load, wait for
inverter to cool
Check cable connection Or contact
technical support
If appliance does not start, then
appliance is drawing excessive wattage
and will not work with inverter
Check the load rating (the startup
power is over 8 times of the rating
power)
Check the cables, and use the correct
size of the cable
Check the battery, and use the correct
battery