6.3. Condition Sensors
a) Seal condition sensors at pumps with oil chamber (mod-
els without cooling jacket or model „U" with cooling jacket
and open circuit cooling):
In case of water entering the oil chamber through the shaft
seals, the resistance will change.
The electrical resistance of the oil in the oil chamber is
measured by 2 sensors.
The sensors must be connected by 2 wires (marked S1
and S2) of the pump connecting cable in the control panel
with a tripping unit with galvanically separated safety circuit
(electrode relay, e.g. HOMA part no.: 1610995).
For explosion-proof models an intrinsically-safe relay
(HOMA part no.: 1416510) must be used.
The tripping unit should have an adjustable sensitivity of 0
to 100 kiloohm, standard setting is approx. 50 kiloohm.
b) Seal condition sensors at pumps without oil chamber,
with cooling jacket and closed (internal) cooling circuit
(model „L"):
A leakage chamber is controlled by two sensors for enter-
ing of cooling liquid (liquid water/glycol).
This leakage chamber is placed between the upper (motor-
side) shaft seal and the bottom ball bearing.
In case of cooling liquid entering the leakage chamber
through the upper shaft seal, the sensors contact.
The sensors must be connected by 2 wires (marked S1
and S2) of the pump connecting cable in the control panel
with a tripping unit with galvanically separated safety circuit
(electrode relay, e.g. HOMA part no.: 1610995).
For explosion-proof models an intrinsically-safe relay
(HOMA part no.: 1416510) must be used.
The tripping unit should have an adjustable sensitivity of 0
to 100 kiloohm, standard setting is approx. 50 kiloohm.
Stator
Stator
winding
winding
Normal
Ex
T1+T3
T1+T2
Regulator
Limiter
140°C
140°C
150°C
150°C
150°C
150°C
150°C
150°C
140°C
140°C
140°C
140°C
140°C
140°C
150°C
150°C
150°C
150°C
150°C
150°C
150°C
150°C
150°C
150°C
150°C
150°C
150°C
150°C
Lower
Upper
bearing
bearing
80°C
80°C
80°C
80°C
90°C
105°C
90°C
105°C
90°C
105°C
90°C
105°C
90°C
105°C
90°C
105°C
90°C
105°C
90°C
105°C
90°C
105°C
90°C
105°C
14