CHARGING INDICATION
Voltage display
The charging voltage will be shown on the display
Low-temp function:
It will start up once the ambient temperature is lower than 10˚ (/ 50 ˚F) automati-
cally.
Charging-error function:
Please refer to the troubleshooting guide below.
Incorrect battery voltage.
Please refer to the troubleshooting guide below.
TROUBLESHOOTING
In case of faults, the LCD indicator will display the following indications:
DISPLAY INDICA-
PROBLEM
TION
Short circuit
Battery unrecoverable after a
complete desulfation cycle.
a) Battery capacity excessive
b) It is a faulty battery, which
will not accept a charge.
Bad power storage
capability
The battery voltage is
too low (<8V) during
Power supply mode.
The Charged LFP
battery is less than 10V
Wrong battery
voltage.
Connect the
a) Circuit open
clamps (+/-) to
or Clamps are not
the battery for
making a good con-
charging.
nection.
The LCD moni-
b) The battery's volt-
tor just stays
in the Standby
age is lower than 2V.
mode.
The LCD
The AC end is not
monitor
making a good
can't be lit
connection.
SOLUTIONS
Check for poor connectionat battery or clamps.
It is a faulty battery – please replace battery
Use a battery charger with greater charging capacity.
It is a faulty battery – please replace battery
It is a faulty battery – please replace battery
Please check if 161123 is connected correctly with a 12V
battery (not a 6V battery).
If you still want to use the function under abnormal situation
after checking, please press and hold the type button for 3
seconds to activate the power supply function MANUALLY.
It is a faulty battery – please replace battery
(You are attempting to charge 24V or more battery).
The 161123 is for 12V battery only. Please use a battery
charger with correct voltage output.
Check for poor connection at battery and ground.
Contact your nearest battery service center or charge the
battery with a manual charger to an OCV of 2V or more
Check for poor connection at the AC side.
8
Vedpak 215_Version 1_10.2016