Setup And Installation

AC Power

Net-X has an internal auto-ranging power supply that works with an input voltage range of
100–240 VAC, 50/60 Hz. To determine the power requirements for the Net-X refer to the
label affixed to the product or Technical Specifications.
The listed rating indicates the maximum current draw during normal operation. For more
information, download Sizing Circuit Breakers from the Chauvet website at
www.chauvetprofessional.com.
·
Always connect this product to a properly grounded and protected circuit.
·
Never connect this product to a rheostat (variable resistor) or dimmer circuit,
even if the rheostat or dimmer channel serves only as a 0 to 100% switch.
·
To eliminate unnecessary wear and improve its lifespan, during periods of non-
use completely disconnect the product from power via breaker or by unplugging
it.

Fuse Replacement

The Net-X uses a T 250 mA, 250 V fuse accessible from the back of the product. To change
the fuse, do the following:
1. Disconnect the product from power.
2. With a flat-head screwdriver, unscrew the fuse holder cap from the
housing.
3. Remove the blown fuse.
4. Replace with a fuse of the same type and rating.
5. Screw the fuse holder cap back in place and reconnect power.
·
Disconnect the product from power before replacing the fuse.
·
Always replace a blown fuse with another of the same type and rating.
Net-X User Manual Rev. 5
Setup And Installation
Page 11 of 65