REARMING BALTIC AUTOMATIC VERSION
Unscrew the used cartridge anticlockwise
1.
ensuring that the green safety indicator
on the label by the inflation mechanism. Replace the cartridge if it has been activated or if it has
passed its expiry date
2015 means it must be replaced before February 2015.
Refit the examined cartridge if ok if not screw in a new cartridge clockwise and tighten it by hand
2.
until no threads are visible.
Unscrew the CO
3.
manner. Check that the lever and the pin (visible at the bottom of the valve head next to the CO
cylinder's fastening)
back in to the normal position and secure it with a new green safety indicator
Visually check that the O-ring in the bottom of the valve head, next to the CO
4.
is undamaged
Screw in a new, clean and unpierced CO
5.
Use no tools.
REARMING BALTIC MANUAL VERSION
Unscrew the CO
1.
manner. Check that the lever and the piercing pin (visible at the bottom of the thread for the CO
cylinder
it by pressing it against the valve head until it clicks into place.
Visually check that the O-ring in the bottom of the valve head, next to the CO
2.
12
is undamaged
Screw in a new, clean and unpierced CO
3.
Use no tools.
When the CO
REPACKING
BEFORE REPACKING
Follow these instructions carefully.
Repacking must be carried out with dry hands, in dry surroundings and without tools.
Place the inflatable lifejacket, back downwards, on a flat surface
Make sure the lifejacket is deflated and the mouth inflation tube's cap is in the normal position
and the indicators show green
BALTIC INFLATABLE LIFEJACKETS WITH ZIPPED PROTECTIVE COVER
Release the zip slider by pulling it to the end of the longer zip
1.
lifejacket. Pull the slider back clockwise, to the right hand side of the lifejacket.
Put the zip together like on a normal jacket
2.
lifejacket, at the same time folding the lung according to the instructions below.
, which is stamped on the side of the cartridge. For example, 02
6
cylinder anticlockwise. Discard the cylinder in an environmentally friendly
2
can move freely, by pulling on the activating cord. Push the lever
12:1
.
12:3
cylinder anticlockwise. Discard the cylinder in an environmentally friendly
2
can move freely, by pulling on the activating cord. Fold back the lever and secure
13:1
.
13:2
cylinder is mounted correctly, the indicator window should be green.
2
7
, and check that the new cartridge is active by
10
is still in place. Follow the illustrated instructions
11
cylinder using only hand force until absolutely tight.
2
cylinder using only hand force until absolutely tight.
2
,
.
8
15
, and pull the slider anticlockwise round the
16
2
.
12:2
cylinder's fastening,
2
2
cylinder's fastening,
2
,
.
14
23
14
, on the left hand side of the