Technical Features - Sime ECOMAXI 90 ErP Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation, use and maintenance manual
3.2

Technical features

Description
Heat output provided HP
Total heat output
Heating time (
)
1
Heating time in BOOST mode
(55°C) (
2
)
Tank dispersion
Electrical specifications
Power supply
Frequency
Maximum consumption HP
Average consumption
Resistor consumption + HP
Electrical resistor output
Type of protection
Operating conditions
Ambient temperature
Ambient relative humidity
Operating temperatures
Maximum temperature HP
Maximum temperature
Compressor
Compressor protection
Fan
Output mouth diameter
Number of revs
Nominal air flow rate
Max. available head
Motor protection
Capacitor
Refrigerant
Load
Nominal
water
capacity
Max. quantity of usable hot
water Vmax(
)
3
Insulation
Defrosting
Unit
kW
kW
H:M
H:M
W
V
Hz
kW
kW
kW
kW
°C
%
°C
°C
mm
rpm
m
/h
3
Pa
g
storage
l
l
EcoMaxi 90 ErP
1,005
2.20
5:30
2:25
33
1/N/230
50
0,270
0,210
1,470
1.2
Single manual-reset safety thermostat
4-43
<90
60
70
Rotary
Automatic-reset thermal circuit breaker
Centrifugal
125
2700
130
120
Internal automatic-reset thermal circuit breaker
Existing encased aluminium pipe
R134a
530
87
95.5
High-density polyurethane foam
Passive air
MANUAL CODE: 6328406
Page 37 / 124

Publicité

Table des Matières
loading

Produits Connexes pour Sime ECOMAXI 90 ErP

Ce manuel est également adapté pour:

8115800

Table des Matières