Operating Instructions • Warning Information • Parts Break­down
Air Supply...
Tools of this class operate on a wide range of air
pressures. It is recommended that air pressure of these tools measures
90 PSI at the tool while running free. Higher pressure (over 90 psig; 6.2
bar) raises performance beyond the rated capacity of the tool which will
shorten tool life because of faster wear and could cause injury.
Always use clean, dry air. Dust, corrosive fumes and/or water in the air
line will cause damage to the tool. Drain the air tank daily. Clean the
air inlet filter screen on at least a weekly schedule. The recommended
hookup procedure can be viewed in figure 1.
The air inlet used for connecting air supply, has
standard 1/4" NPT. Line pressure should be increased to compensate
for unusually long air hoses (over 25 feet). Minimum hose diameter
should be 3/8" I.D. and fittings should have the same inside dimensions
and be tightly secured.
Lubrication...
Lubricate the cylinder daily with quality air tool oil. If no air line oiler is
used, run a teaspoon of oil through the tool. The oil can be squirted into
the tool air inlet or into the hose at the nearest connection to the air
supply, then run the tool.
Limited Warranty...
SUNEX INTERNATIONAL, INC. WARRANTS TO ITS CUSTOMERS THAT THE COMPANY'S SUNEX TOOLS
PRODUCTS ARE FREE FROM DEFECTS IN WORKMANSHIP AND MATERIALS.
Sunex International, Inc. will repair or replace its Sunex Tools ® branded products which fail to give satisfactory service due to defective
workmanship or materials, based upon the terms and conditions of the following described warranty plans attributed to that specific product.
This product carries a ONE-YEAR warranty. During this warranty period, Sunex Tools will repair or replace at our option any part or unit which
proves to be defective in material or workmanship.
Other important warranty information...
This warranty does not cover damage to equipment or tools arising from alteration, abuse, misuse, damage and does not cover any repairs or
replacement made by anyone other than Sunex Tools or its authorized warranty service centers. The foregoing obligation is Sunex Tools' sole
liability under this or any implied warranty and under no circumstances shall we be liable for any incidental or consequential damages.
Note: Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion
may not apply to you. Return equipment or parts to Sunex Tools, or an authorized warranty service center, transportation prepaid. Be
certain to include your name and address, evidence of the purchase date, and description of the suspected defect.
If you have any questions about warranty service, please write to Sunex Tools. This warranty gives you specific legal rights and you may also
have other rights which vary from state to state. Repair kits and replacement parts are available for many of Sunex Tools products regardless
of whether or not the product is still covered by a warranty plan.
SHIPPINg ADDRESS: Sunex Tools • 35 Hawkins Rd. • Travelers Rest, SC 29690
MAILINg ADDRESS: Sunex Tools • P.O. Box 425 • Greenville, SC 29608
SX246: Parts Breakdown & Operating Manual
Nipple
Operation...
Make sure needle housing is tightened securely on cylinder
before operating tool.
To Change Needles:
Remove front retaining ring (#19) and slide plunger (#20), return
spring (#21) and needle holder (#22) out from front of needle
housing (#25).
Remove old needles from holder (#22) and insert new ones. The
holes in the needle holder are countersunk; make sure needles
drop inside holder so that top of each needle is flush with top of
holder.
To regulate air, turn air regulator knob (#18) out (counterclockwise)
for maximum air pressure and in (clockwise) for minimum air
pressure.