Nipple
Air Supply...
Tools of this class operate on a wide range of air pressures .
It is recommended that air pressure of these tools measures 90
PSI at the tool while running free . Higher pressure (over 90 psig;
6 .2 bar) raises performance beyond the rated capacity of the tool
which will shorten tool life because of faster wear and could cause
injury .
Always use clean, dry air . Dust, corrosive fumes and/or
water in the air line will cause damage to the tool . Drain
the air tank daily . Clean the air inlet filter screen on
at least a weekly schedule . The recommended hookup
procedure can be viewed in the above figure .
The air inlet used for connecting air supply, has standard 1⁄4" NPT .
Line pressure should be increased to compensate for unusually
long air hoses (over 25 feet) . Minimum hose diameter should be
3/8" I .D . and fittings should have the same inside dimensions and
be tightly secured .
Lubrication...
Lubricate the air motor daily with air tool oil . If no air line oiler is
used, run 1/2 oz . of oil through the tool . The oil can be squirted into
the tool air inlet or into the hose at the nearest connection to the
air supply, then run the tool . Overfilling will cause a reduction in the
power of the tool .
Limited Warranty...
SUNEX INTERNATIONAL, INC. WARRANTS TO ITS CUSTOMERS THAT THE COMPANY'S
SUNEX TOOLS ® BRANDED PRODUCTS ARE FREE FROM DEFECTS IN WORKMANSHIP
AND MATERIALS.
Sunex­ International, Inc . will replace any SXC Series Air Tool which fails to give satisfactory service due to defective workmanship or materials .
This product carries a ONE-YEAR warranty . During this warranty period, Sunex­ Tools will replace free of charge any part or unit which proves to
be defective in material or workmanship .
Other important warranty information...
This warranty does not cover damage to equipment or tools arising from alteration, abuse, misuse, damage and does not cover any repairs or
replacement made by anyone other than Sunex­ Tools or its authorized warranty service centers . The foregoing obligation is Sunex­ Tools' sole
liability under this or any implied warranty and under no circumstances shall we be liable for any incidental or consequential damages .
Note: Some states do not allow the ex­clusion or limitation of incidental or consequential damages, so the above
limitation or ex­clusion may not apply to you . Return tool to Sunex­ Tools, transportation prepaid . Be certain to include your name and address,
evidence of the purchase date, and description of the suspected defect .
If you have any questions about warranty service, please write to Sunex­ Tools . This warranty gives you specific legal rights and you may also
have other rights which vary from state to state . After the one year direct replacement warranty has ex­pired, some service parts are available for
purchase through normal Sunex­ Tools service options .
Shipping Address: Sunex Tools • 315 Hawkins Rd . • Travelers Rest, SC 29690
Mailing Address: Sunex Tools • P .O . Box­ 4215 • Greenville, SC 29608
SXC601: Parts Breakdown & Operating Manual
Operation...
When using the pin stripe removal tool be careful not to ex­ert
ex­cessive force .
The burning of the work piece or ex­cessive speed reduction indi-
cates too much force being applied . Changing to a free cutting tool
may be better for the desired rate of speed and stock removal .
Avoid hazardous conditions by making sure there is sufficient force
on the spindle of the cutting tool by placing the spindle 7/16" or
more inside the collet .