INSTALLATION PROCEDURE (Manway Flanges From 35" (889mm) to 54" (1370mm) Diameter)
1) Remove manway hatch cover as required.
EN
2) Install Base Center Assembly on manway flange, ensure Mounting Post is vertical and tighten clamps
securely using only the attached Clamp Wrench.
3) Insert upper Mounting Leg Assembly, ensure Klik connector engages completely, position clamp
assembly on manway flange, and tighten securely using only the attached Clamp Wrench.
4) Insert lower Mounting Leg Assembly, ensure Klik connector engages completely, position clamp
assembly on manway flange, and tighten securely using only the attached Clamp Wrench.
5) Adjust Mounting Post Height position as required, install Arm Assembly onto Mounting Post, and adjust
Arm Assembly horizontal position to center arm in manway.
5) Install Winch and any other accessories following manuafacturer's instructions supplied.
9