SeCtIOn 3 |
An additional external fuse (not provided) must be connected to the battery connection
cable, close to the battery pole. the external fuse prevents cable short circuits. A 40A
fuse can be used for all controller types.
!
WARninG!
Danger of explosion from sparking! Danger of electric shock! Solar modules generate
electricity under incident light. the full voltage is present, even when the incident light
levels are low.
-
Protect the solar modules from incident light during installation, e.g. cover them.
-
never touch uninsulated cable ends.
-
Use only insulated tools.
-
ensure that all loads to be connected are switched oFF. if necessary, remove the
fuse.
-
connections must always be made in the sequence described below.
M
Solar
2
Module
8 | SAMLEX AMERICA INC.

Installation

2b 2c
1 2a
3
A+
M-
battery
(40A fuse at A+)
2d
4
5
A-
1
L
L-
3
Load