SeCtIOn 6 |
iSSUe
LoAD CANNoT be
oPerATeD
+
INfo LeD (1)
fLASheS reD
+
greeN LeD (2d)
fLASheS
LoAD CANNoT
be oPerATeD
+
INfo LeD (1)
ILLUMINATeS greeN
bATTery IS
NoT ChArgeD
bATTery DISPLAy
jUMPS qUICKLy
troubleshooting
cAUSe
Load output is
switched off due
to excessive battery
voltage
Incorrect grounding
external charging
source is not voltage-
limited
Defective load or
installation error
Solar module not
connected
Solar module
connected with
incorrect polarity
Short circuit at solar
module input
Incorrect solar module
voltage
Solar module defective
Large pulse current
battery is defective
ReMeDy
The load output automatically
switched on again as soon as the
battery voltage lies within the per-
missible range
Check the grounding. grounding
is allowed only on the Negative
battery Terminal
- Check the external charging
source
- If necessary, switch off external
charging source
- Connect load correctly
- replace load
Connect the solar module
Connect the solar module with
the correct polarity
Correct the cause of the short
circuit
Use a solar module of the speci-
fied voltage
replace the solar module
Adjust the current consumption to
match the battery capacity
replace the battery
SAMLEX AMERICA INC. | 13