SeCtIOn 3 |
Accessories provided
for installation
6 pieces of Twist-on Wire Nut connectors
have been provided for connection of
input and output wiring.
First, insert two wires together into con-
nector cap, and then turn the cap until the
two wires twisted tightly. follow sequence
1 to 4 shown in the pictures given below.
PV Panel
Figure 3.1:
Layout & Installation Diagram
Installation & Operation
PV+
PV-
1
2
8
Lead Acid battery
Layout of input and
output connections
The layout of the various input / output
wires is shown in fig. 3.1 below:
Fig 3.1 Legend:
1. Yellow wire PV +
Connects to the Positive terminal of
the Solar Panel
2. Black wire PV -
Connects to the Negative terminal of the
Solar Panel
3. Red wire Bat +
Connects to the Positive terminal of the battery
through a 10 A fuse
4. Black wire Bat -
Connects to the Negative terminal of the battery
5. White wire Load +
Connects to the Positive terminal of the load
(DC lamp) for Night Light Function
6. Black wire Load -
Connects to the Negative terminal of the load
(DC lamp) for Night Light Function
7. Blue wire Wet type battery
Is not connected if the battery is sealed type
(AGM). Is connected to the Bat – (4) if the battery
is Flooded / Wet Cell type
8. External fuse, 32 V, 10 A
Bat+ bat- Load+ Load-
3
4
5
6
Wet Type
battery
7
DC Lamp
earth Ground