ELETRODES – NOZZLE
Remove the cover, disconnect the high voltage cables from transformer side, remove the photoresistor 1, loosen the fittings
connecting the light oil pipelines to the nozzle lines, loosen the screws of the upper plate and pull it out with the set flange-
nozzle-deflector-electrodes.
Loosen the screws 5 to remove the deflector and loosen screws 6 to remove the electrodes. Clean the nozzle by removing
the filter and cleaning the slots and the atomisation hole by gasoline. Rinse it with oil.
On reinstalling the unit make sure that the position of the electrodes-deflector is correct.
6
5
pag. 75
G 50/2 oil