§ If the blade is damaged or worn, fit a new blade.
Observe the following
§ Disconnect the mower from the mains and wait
until the blade has stopped rotating before
proceeding.
§ Be careful not to cut yourself. Use heavy-duty
gloves or a cloth to grip the blade.
§ Only use the specified replacement blade.
§ Do not remove the impeller (A)for any reason.
> Replacing the blade
For safety reasons, we recommend having the
blade replaced by an authorized professional.
Important: Wear work gloves!
Replacement blade,
as this will ensure top performance and safety under
all conditions. Carry
out the following steps to change the blade:
§ Turn the mower onto its side.
§ Grip the blade with one hand.
§ Use the spanner supplied to loosen and remove
the blade nut.
§ Replace the blade
§ Securely tighten the blade nut.
TECHNICAL DATA
Rated Voltage
Rated Frequency
Rated Power
Rotation speed
Cutting width
Blade
Protection class
Int. protection degree
Collect box / bag
Cutting heights
Self/drive speed
Induction motor
Weight
Noise emission values measured according to
relevant standard :
Acoustic pressure level LpA
83.4 dB(A)
Acoustic power level LwA
93 dB(A)
Warning!
precautions:
«
Fig E »
230V
50Hz
1800W
-1
2800 min
460 mm
MARK
Class II
IPX4
65 L
25,31,37,43,50 mm
0.46m/s
Yes
27.2 Kg
K = 3dB(A)
K = 3 dB(A)
The sound power pressure may
exceed 85 dB(A), in this case
individual hearing protection
Weighted root mean square acceleration according
to relevant standard. : 2.21 m/s²
The declared vibration total value has
been measured in accordance with a standard
test method and may be used for comparing one
tool with another that the declared vibration total
value may also be used in a preliminary
assessment of exposure.
A warning that the vibration emission
during actual use of the power tool can differ
from the declared total value depending on the
ways in which the tool is used and of the need to
identify safety measures to protect the operator
that are based on an estimation of exposure in
the actual conditions of use (taking account of
all parts of the operating cycle such as the times
when the tool is switched off and when it is
running idle in addition to the trigger time).
SERVICE DEPARTMENT
_ Damaged switches must be replaced by our after-
sales service department.
_ If replacing the power cord is necessary, it
should be done by the manufacturer or his agent
to avoid a hazard.
AFTER-SALES SERVICE AND
APPLICATION SERVICE
Our after-sales service responds to your questions
concerning maintenance and repair of your product
as well as spare parts. Exploded views and
information on spare parts can also be found
under:www.eco-repa.com
ELEM GARDEN TECHNIC application service team
will gladly answer questions concerning our
products and their accessories : sav@eco-repa.com
ATTENTION !
must be worn.
K = 1.5 m/s²
37