Technical Specifications - purline PLQ10M Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

TROUBLE-SHOOTING
PROBABLE
TROUBLE
CAUSE
No power or
incorrect voltage
Compressor & fan
Faulty plug.
do not run.
Short circuit
Defrosting in
progress
Allow 3 mn for
Fan runs but not
delayed start.
compressor.
Ambient
temperature too
low
Uneven floor
Compressor or
Very noisy unit
motor are lost.
« You can hear
running liquid »
Dirty filter
Refrigerant
leaking.
No or insufficient
Ambient
dehumidification.
temperature too
low- No humidity
to remove
Filter too dirty.
Evaporator covered
Ambient
with frost.
temperature too
low.
Overflowing or
Water tank leak
SOLUTION
Check with an
electrician.
Check with an
electrician.
Wait for end of cycle
Normal, will start
after 3 minutes.
Normal, compressor
protection
Install unit on a hard
level surface
Check with SAV
Normal :refrigerant is
flowing through the
coils..
Clean filter.
Check with SAV
Check temperature &
humidity of the room.
Clean filter
Normal
Replace tank
leaking water tank
Faulty full tank
auto switch
PLEASE NOTE
Excessive dampness will quickly be reduced from the air.
However if the location where the unit is operating is extremely
damp, you will need a few days or even weeks before you start
obtain a comfortable humidity rate.
Condensation on a cold surface is NORMAL. The dehumidifier
reduces the air humidity rate and you should notice less
condensation on cold windows.
IMPORTANT: IT IS NECESSARY TO WAIT 2 TO 3 MINUTES
BEFORE RESTARTING THE UNIT WHEN IT HAS BEEN
SHUT OFF. THIS ALLOWS THE REFRIFERATION SYSTEM
TO STABILIZE.

Technical specifications

Recommended room temperature :
Dehumidification capacity :
Tank capacity :
Net weight :
Dimensions (L x P x H)
Power consumption :
Input voltage
Réfrigérant
Characteristics prone to change without notice
WARRANTY:
The warranty is valid for 2 years for a "manufacturing fault".
To benefit from the warranty, please return the device to your dealer
with POSTAGE PAID along with the document of purchase proof
Check with SAV
De 5°C à 35°C
10 l/DAY at
30°C/80 % H.R
3.6 litres
11.5 Kg
342 x 245 x 492mm
260 W / 1.32A
230V-240V ~ 50 Hz
R134a