4.2
ELECTRICAL CONNECTION
The electrical connection of the pump to the network must be done with the appropriate power cord (3G1mm
H05RR-F) to the enclosed connector. The manual for the connector is in the plastic bag within the pump
packaging.
The pump has a built-in overcurrent fuse and protection, temperature protection and basic overvoltage
protection. It doesn't need an additional thermal protection switch. Connection leads should be capable of
carrying rated power and should be properly fused. Ground lead connection is essential for safety and should be
connected first! Grounding is only meant for pump safety. Pipe systems should be grounded separately!
Electrical connection of the pump should be conducted by trained and qualified personnel!
The cable connection must be done in a manner that ensures that the cable is never in contact
with the casing of the device, due to the high temperature of the casing.
Devices for separating all phases from the power supply must be installed in the electric
installation in accordance with the national installation regulations.
This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a safe way and understand
the hazards involved.
Children shall not play with the appliance.
2
,