attENtiON
The ES-90/005 control box is delivered without
cables for external field wiring.
All interconnect cables/wire size used shall comply
with the local requirements.
The glands used for inserting the cable into the
ES-90/005 control box should be placed in the
bottom of the casing.
The cable should fit tightly in the gland to prevent
any moisture entering the inside of the ES-90/005
control box.
4.1
unpacking
Check that the product is complete. The package should
contain:
- ES-90/005 control box
- door key
- MCC-05
4.2

Electric connection

Connect the ES-90/005 in accordance with the separately
supplied electrical diagram.
attENtiON
The default setting of the thermal overload in the
control box is 3~. Change in case of 1~ according
to the electrical diagram.
cautiON!
Electric connection to be executed in accordance
with local requirements. Ensure compliance with the
EMC regulatory arrangements.
waRNiNg!
Make sure the machine is suitable for connection to
the local mains. Information about the connection
voltage and frequency can be found on the
identification plate.
attENtiON
The thermal relay should be set according to the
overload mentioned on the identification plate on
the motor.
5

MaiNtENaNcE

The ES-90/005 requires no specific maintenance.
6

tROubLEShOOtiNg

If the ES-90/005 does not function (correctly), please contact
your supplier.
7

SpaRE paRtS

The following spare parts are available for the ES-90/005.
7.1
ES-90/005 50 hz
Refer to Fig. I on page 25.
Ref. art. no.
Description
A
0000101414
Relay K12 24V AC 50-60Hz
B
0000101413
Transformer 120-575V 24V 75VA
C
0000101415
Fuse 1,6A 5 x 20 mm UL
D
0000101409
Fuse 3,15A 5 x 20 mm UL
E
0000101410
PCB ICE with buttons
F
0000100705
MCC-05 sensor
0000101011/190712/0 ES-90/005
7.2
ES-90/005 60 hz
Refer to Fig. II on page 25.
Ref. art. no.
Description
A
0000101440
Relay 100-C23KJ10
B
0000101442
Thermal relay 3,2-16A
C
0000101444
Fuse class CC 0,5A
D
0000101409
Fuse 3,15A 5 x 20 mm UL
E
0000101410
PCB ICE with buttons
F
0000100682
Transformer 120-575V 24V 75 VA
G
0000100705
MCC-05 sensor
8

ELEctRicaL DiagRaM

Refer to the separately supplied electrical diagram.
9

DiSpOSaL

After life of the product, dispose it of in accordance with state
or local regulations.

cE DEcLaRatiON

CE declaration of conformity for machinery
We, Plymovent Manufacturing B.V., Wezelkoog 11, 1822 BL
Alkmaar, the Netherlands, herewith declare, on our own
responsibility, that the product(s):
- ES-90/005
which this declaration refers to, is in accordance with the
conditions of the following Directives:
- EMC 2004/108 EC
- LVD 2006/95 EC
and is/are in conformity with the following harmonized
standard(s) and/or other such normative documents +
amendments, if any:
- EN ISO 61000-2
- EN ISO 61000-6
Alkmaar, the Netherlands, 1 September 2012
Ir. F. Coehoorn
Vice President Research & Development
EN - 5

Publicité

Table des Matières
loading

Table des Matières