Télécharger Imprimer la page

Leroy Somer CDF 9 Notice D'installation page 2

Publicité

Les langues disponibles

Les langues disponibles

LEROY-SOMER
1 - PRINCIPLE
The CDF 9 booster allows to feed one or several DC brakes directly from the AC power supply. Two functions are integrated in
the sequence.
A 1s over voltage time is applied on the electromagnets of the brake to ensure a fast response time. Then this voltage is reduced
sufficiently to ensure the brake to stay on position and to reduce the heating of the coils.
2 - GENERAL DATA
Mounting
Protection
Ambient temperature
Relative humidity
Storage or transport temperature
Shocks
Vibrations
Terminal cross section
Weight
3 - ELECTRICAL DATA
AC supply voltage and frequency
DC boost output
DC hold output
Maximum current
Boost time
Starting delay
4 - MECHANICAL INSTALLATION
• The CDF 9 module is intended to be mounted in an enclosure which prevents access except by trained and
authorised personnel and which prevents the ingress of contamination.
• It is designed for use in an environment classified as pollution degree 2 in accordance with IEC 60664-1. This
means that only dry, non conducting contamination is acceptable.
CDF 9 dimensions (in mm):
Removal screw
terminal block
The DIN rail mounting mechanism has been designed so no tools are required to install the module.
5 - ELECTRICAL INSTALLATION
The voltages used in the module can cause severe electric shock and/or burns, and could be lethal. Extreme care is necessary at
all times when working with or adjacent to the module.
The CDF 9 module is intended as a component for professional incorporation into complete equipment or system.
System design, installation, commissioning and maintenance must be carried out by personnel who have the necessary training
and experience.
Wiring diagram:
Please visite our website www.leroy-somer.com for details.
6 - MAINTENANCE
The CDF 9 module does not request any specific maintenance.
2
INSTALLATION MANUAL
CDF 9
Boost supply for DC brake
DIN RAIL ref EN50022 - NFC 63015 - DIN 46277-3
IP20 (connector excluded)
-16°C to 55°C (-25°C to 85°C with derating)
98% max (without condensation)
-40°C to 100°C
< 100m/s² 16ms (IEC 60068-2-29)
< 5m/s², 10 to 150Hz (IEC 60068-2-6)
max 2.5 mm²
200g
220V to 480V (-15%, +6%), 50/60Hz
0.90 x (AC supply), 207Vdc for 230Vac
0.45 x (AC supply), 104Vdc for 230Vac
3.5 A RMS (5s integration)
1000ms
15ms max
45
DIN Rail
35 25
45,5
62
11,5
11,5
90
95
7,5
4719 en - 2012.03 / b