Airflow Control Technology (Act) - Zephyr Siena ZSI-E30BS Guide D'utilisation, D'entretien Et D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Airflow Control Technology (ACT)

Some local codes limit the maximum amount of CFM a range hood can move. ACT allows you to control the
maximum blower CFM of select Zephyr Ventilation range hoods without the need for expensive make up air kits.
ACT enables the installer to easily set the maximum blower speed to one of two most commonly specified CFM
levels; 390 or 290 CFM. The usage of ACT may not be necessary for your installation. Please check your local
codes for CFM restrictions.
By default the maximum blower CFM is set to 650.
!
CAUTION:
Hood must be disconnected from main power prior to performing the
conversion instructions listed below. Failure to do so could result in
personal injury or damage to the product.
To enable ACT
1. Before hood installation, gain access to PC board by following the steps shown in FIG. D.
2. Change plastic jumper positioning as shown in FIG. E to set the desired maximum blower CFM.
3. Re-install PC board & continue with hood installation.
4. Remove the appropriate foil CFM sticker included with the hood literature and place inside the hood body below
the wiring diagram or in another clearly visible location.
NOTE: After re-positioning the jumper and powering on the hood, the CFM cannot be changed again.
To verify if your installer enabled ACT
With hood off, press and hold the power button for three seconds. If 5 LEDs illuminate = defualt max. CFM, if 4
LEDs illuminate = max. 390 CFM, and if 3 LEDs illuminate = max. 290 CFM.
When ACT is enabled, the number of blower speeds will be reduced. 390 CFM = max. 4 speeds and 290 CFM =
max. 3 speeds.
There should also be a foil label located inside the hood body near the wiring diagram that indicates the blower
CFM.
ccessing PC Board Instructions
Model: ZSI
er housing.
- PC board located behind the light panel.
- Remove aluminum mesh filters.
board cover.
- Remove 2 screws attaching light panel.
Model: AK92
- PC board located behind the light panel.
- Remove baffle filters and residue tray.
board cover.
- (AK9228AS only) Remove both spacer panels by 2
screws for each spacer panel.
- Remove 5 screws attaching light panel.
anel.
applicable) by 2 screws for each spacer panel.
nel.
FIG. D
Default Max. Blower CFM
7
8
7
5
6
3
4
1
2
5
3
1
J u m p e r
Max. Blower CFM
390
PC Board
FIG. E
17
Jumper Pins
Plastic
7
8
Jumper
5
6
3
4
1
2
J u m p e r
5 - 6 or 7-8
DEFAULT POSITION
8
7
8
6
5
6
4
3
4
2
1
2
3 - 4
J u m p e r
1 - 2
Max. Blower CFM
290

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Siena zsi-e36bs

Table des Matières