Temperature ( Instrument versions only)

It is possible to select one of the following operational modes:
MANUAL – the value set in the configuration menu by the user, is the reference parameter for the
compensation of the pH value.
AUTOMATIC - The value measured by the probe is the reference parameter for the compensation of the
Ph value. In the menu "MODE PH, RX, CL, PPM" the "TEMP" menu appears.

Activation delay ( Instrument versions only)

If there is a need to delay the operation of the pump you can set a delay in the following time in the following scale:
0"  60'

Mode menu (Instrument versions only)

In order to simplify the definition of the various functions we have introduced two selections that allow you to modify the
complexity level of the programming:
FULL - All functions are available.
BASIC - Only the main functions are available.
You can set a time after which the display will automatically exit the programming menu. The default time is 2'.
Language
You can select one of the following languages for the display messages.
Italian
English
Res et
The device is equipped with two reset levels, the user can choose between the following two possibilities:
PARTIAL RESET - The pump remains in the selected operating mode (proportional or control), but all
factory settings are restored and all user settings deleted.
TOTAL RESET - The pump returns to its factory settings, at reboot you will need to set the operating
mode you want to activate: VFT, VFT-S, MF, ST, VFT-T, VFT-S-T, MF-T, ST-T, as per the table.
ENGLISH 111