Page 1
PLUS www.etatronds.com NORME DI INSTALLAZIONE, USO E MANUTENZIONE OPERATING INSTRUCTIONS AND MAINTENANCE NOTICE D’INSTALLATION, EMPLOI ET ENTRETIEN UNI EN ISO 9001-2008...
Page 4
(IT) DIRETTIVA "RAEE" 2002/96/CE E SUCCESSIVA MODIFICA 2003/108/CE SUI RIFIUTI DI APPARECCHIATURE ELETTRICHE ED ELETTRONICHE Il simbolo sotto riportato indica che il prodotto non può essere smaltito come normale rifiuto urbano. Le Apparecchiature Elettriche ed Elettroniche (AEE) possono contenere materiali nocivi per l'ambiente e la salute e pertanto devono essere oggetto di raccolta differenziata: smaltite quindi presso apposite discariche o riconsegnate al distributore a fronte dell'acquisto di una nuova, di tipo equivalente o facente le stesse funzioni.
Sm ont aggio ............................9 Ga ran zia ..............................9 POMPE DOSATRICI SERIE EONE PLUS ........................10 P rin cip io di fun z io n am en to ........................10 Ca ratt e rist ich e te cn ich e ........................10 No rm e d i ri fe rim en to ........
Page 6
P ropo r ziona l e p p m ( VFT - S, MF, VFT - S-T, MF -T ) ..................21 P ropo r ziona le m A (V FT - S , MF, VFT - S- T, MF -T ) ..................21 DIAGRAMMI FUNZIONI OPERATIVE DELLA POMPA PLUS “PROPORZIONALE”...
Page 7
Diag r am m a di f lu ss o so tt o m en ù T EL E CO M A ND O/L IV EL L O/ P RO S SI MIT A’ ..........45 Diag r am m a di f lu ss o so tt o m en ù PO RT AT A P ER IM P UL SO (solo p rop o rz ion a li) ........45 Diag r am m a di f lu ss o so tt o m en ù...
NORME DI SICUREZZA Avvertenze Leggere attentamente le avvertenze sotto elencate in quanto forniscono importanti indicazioni riguardanti la sicurezza di installazione, d’uso e manutenzione. Conservare con cura questo manuale per ogni ulteriore consultazione. NOTA BENE: La pompa è costruita a regola d’arte. La sua durata, affidabilità elettrica e meccanica, saranno maggiori se essa verrà...
(guanti, occhiali, tute, ecc.). Montaggio Tutte le pompe dosatrici dalla Etatron DS prodotte vengono normalmente fornite già assemblate. Per maggiore chiarezza di esposizione si può consultare l’allegato in fondo al manuale dove sono riportati nei disegni in esploso delle pompe, tutti i particolari con relativa nomenclatura, in modo tale da poter avere un quadro completo dei componenti della pompa.
POMPE DOSATRICI SERIE EONE PLUS Principio di funzionamento II funzionamento della pompa dosatrice è assicurato da una membrana in PTFE (teflon®) montata sul pistone di un elettromagnete. Quando il pistone dell’elettromagnete viene attratto, si produce una pressione nel corpo pompa con una espulsione di liquido dalla valvola di mandata.
Principali funzioni supplementari: Funzione Descrizione La pompa controlla a mezzo flusso-stato (disponibile su richiesta e inserito sulla mandata della ALLARME pompa), le iniezioni che sono effettivamente erogate segnalando, eventuali anomalie, tramite FLUSSOSTATO accensione del led di allarme e commutazione dell’apposito relè (se attivato). Operativo se abilitato in tutte le modalità...
La pompa è dotata di una scheda di alimentazione che regola la potenza assorbita in funzione della contro pressione di funzionamento. (esclusa la serie BASIC). Nella tabella seguente sono riportate le caratteristiche tecniche della serie eOne e le corrispondenti curve di portata: Tipo Portata alla Pressione max Pressione...
Materiali a contatto con l’additivo Nella configurazione standard le pompe della serie “eOne” sono fornite con i seguenti materiali: Corpo Membrana Tenute Valvole Raccordi Tubi Cassa pompa CERAMICA PVDF PTFE TFE/P PVDF PE / PVC TFE/P INSTALLAZIONE Premessa Questa sezione descrive le operazioni da eseguire per installare la pompa, i tubi e per il cablaggio elettrico. Leggere attentamente queste istruzioni prima di iniziare qualsiasi attività.
Collegamento elettrico Rispettare le norme in vigore nei diversi paesi per quanto riguarda l’installazione elettrica. Se il cavo di alimentazione è privo di spina elettrica, l’apparecchiatura deve essere collegata alla rete di alimentazione tramite un interruttore omnipolare sezionatore avente una distanza minima tra i contatti di mm. 3. Prima di accedere ai dispositivi di collegamento, tutti i circuiti di alimentazione devono essere interrotti (fig.
Fig.5 – Azionamento spurgo per adescamento Funzione Priming Al fine di agevolare l’adescamento la pompa è dotata di una funzione PRIMING. Si raccomanda di aprire il by-pass di spurgo sul corpo pompa (per le idrauliche che ne sono dotate) durante le operazioni di priming. Il raccordo di spurgo aria deve essere sempre collegato al relativo tubetto con ritorno nel serbatoio di aspirazione.
Schema di impianto tipico Raccordo di iniezione Valvola di iniezione Valvola di contropressione Manometro Valvola di sfioro Presa per alimentazione elettrica Serbatoio additivo Filtro di fondo Sonda di livello Fig. 6 – Impianto tipico Sia sul tubo di mandata che su quello di aspirazione evitare curve eccessive al fine di evitare strozzature sul tubo stesso.
sostituire il tubetto PVC trasparente flessibile di aspirazione con un tubetto in polietilene semi rigido di mandata. togliere preventivamente dal corpo pompa tutta l’acqua presente, infatti se questa si miscela con l’acido solforico genera una forte concentrazione di gas con conseguente surriscaldamento della zona interessata arrecando danni alle valvole ed al corpo pompa.
Pompa Proporzionale e Strumentale PLUS La pompa dosatrice può funzionare sia in modalità Proporzionale che strumentale misuratore pH, Rx o ppm. Alla prima accensione è possibile scegliere la configurazione operativa dell’apparecchiatura. Con riferimento alla seguente tabella l’operatore può selezionare la modalità che meglio si adatta alle proprie esigenze di dosaggio: saranno infatti resi disponibili solo alcuni dei numerosi menù...
SCHEMA DEI COLLEGAMENTI ELETTRICI ALLE PERIFERICHE Per collegare gli accessori e le periferiche alla pompa rimuovere il coperchio frontale “1”, agendo con un giravite a punta piatta sulle due viti in plastica, per accedere alla morsettiera di collegamento (vedi fig. 9) La morsettiera “3”...
FUNZIONI OPERATIVE DELLA POMPA PLUS “PROPORZIONALE” Al fine di agevolare la consultazione del presente manuale, nei titoli dei sottoparagrafi è indicata la configurazione comprendente la funzione descritta. Manuale Questa configurazione è presente in tutte le versioni. La pompa dosatrice lavora ad una frequenza prestabilita dall’utente e compresa nei seguenti range: ...
% SOLUZIONE Generalmente l’additivo che deve essere dosato dalla pompa fa parte di una soluzione acquosa in una determinata percentuale, impostare tale valore per mezzo delle apposite frecce della tastiera: 1 – 100 % IMPOSTA ml x m mpostare il valore in mlxm che si deve garantire nell’impianto.
DIAGRAMMI FUNZIONI OPERATIVE DELLA POMPA PLUS “PROPORZIONALE” Diagramma flusso menù principale Premere il tasto INIZIO START/STOP per entrare nel MENU’ MODO OPERATIVO MODO MANUALE MODO OPERATIVO MODO 1xN MODO OPERATIVO MODO 1xN(M) MODO OPERATIVO MODO 1÷N MODO OPERATIVO MODO ml x I MODO OPERATIVO MODO l x I MODO OPERATIVO...
Diagramma di flusso modo manuale MODO OPERATIVO MODO MANUALE MODO MANUALE MODO MANUALE MODO MANUALE IMPULSI/MINUTO IMPULSI/ORA IMPULSI/GIORNO IMPULSI/MINUTO N. IMPULSI: PULSES/MINUTE MODE IMPULSI/ORA N. IMPULSI: PULSES/MINUTE MODE IMPULSI/GIORNO N. IMPULSI: PULSES/MINUTE MODE Diagramma di flusso modo 1xN MODO OPERATIVO MODO 1xN MODO 1xN...
Diagramma di flusso modo 1 ÷ N MODO OPERATIVO MODO 1÷N MODO 1÷N N. IMPULSI: Diagramma di flusso modo ml x P MODO OPERATIVO MODO ml x I MODO ml x I SOLUZIONE: 100% MODO ml x I ...
Diagramma di flusso modo ml x m MODO OPERATIVO MODO ml x m L/I CONTATORE 0.10 l SOLUZIONE 10.0 % PULSES/MINUTE MODE QUANTITA’ ml x m Diagramma di flusso modo PPM MODO OPERATIVO MODO PPM L/I CONTATORE ...
Diagramma di flusso modo mA MODO OPERATIVO MODO mA IMP. SOGLIA IMP. SOGLIA 20.0 IMPULSI/MIN N. IMP/MIN: IMPULSI/MIN N. IMP./MIN: SOTTO SOTTO FERMA CONTINUA SOPRA SOPRA FERMA CONTINUA ITALIANO...
FUNZIONI OPERATIVE DELLA POMPA PLUS “STRUMENTALE” Selezionando le configurazioni: ST ed ST-T, la pompa dosatrice si pone nella modalità strumentale e in funzione del tipo di parametro elettrochimico selezionato (pH, RX, Cl ppm, ppm), interviene, mantenendo il corretto valore impostato. Una volta stabilita la configurazione strumentale è...
BNC, i restanti due cavi debbono essere inseriti nel passacavo e collegati alla morsettiera “ingressi” della pompa (vedi fig. 10). Nel listino Etatron è possibile verificare la disponibilità dei diversi tipi di sensori. Le sonde per specie chimiche si collegano alla pompa come indicato in fig. 11 Nel menù...
DIAGRAMMI FUNZIONI OPERATIVE DELLA POMPA PLUS “STRUMENTALE” Diagramma flusso menù principale Premere il tasto INIZIO START/STOP per entrare nel MENU’ MODO OPERATIVO MODO MANUALE MODO OPERATIVO MODO pH MODO OPERATIVO FUNZIONI MODO Rx ACCESSORIE MODO OPERATIVO MODO OPERATIVO MODO Cl TIMER MODO OPERATIVO MODO OPERATIVO...
Diagramma di flusso modalità PH MODO OPERATIVO MODO pH MODO pH MENU’ CONFIG. SETPOINT CONFIG. SETPOINT MODO pH MENU’ CALIBRAZIONE CALIBRAZIONE MODO pH MENU’ TEMPERATURA TEMPERATURA MODO pH MENU’ USCITA mA USCITA mA Diagrammi di flusso sottomenù modalità pH MENÙ MODO pH DI BASE CONFIG.
Page 31
MENÙ MODO pH ESTESO CONFIG. SETPOINT VALORE SETPOINT 7.20 TIPO INTERVENTO TIPO INTERVENTO ACIDO ALKALINO VALORE ISTERESI 0.10 MODO INTERVENTO MODO INTERVENTO PROPORZIONALE MANUALE PORTATA MISURA MASSIMA N. IMP/MIN: RITARDO ATTIVAZ.
Page 32
MODO pH MODO pH CALIBRAZIONE TEMPERATURA CALIBRA SET1 TEMPERATURA #.## 7.00 25°C 77°F CALIBRA SET2 #.## 4.00 MODO pH USCITA mA IMP.SOGLIA (1) 4.00 IMP. SOGLIA (2) 7.00 USCITA mA (1) ...
Diagramma di flusso modalità Rx MODO OPERATIVO MODO Rx MODO Rx MENU’ CONFIG. SETPOINT CONFIG. SETPOINT MODO Rx MENU’ CALIBRAZIONE CALIBRAZIONE MODO Rx MENU’ TEMPERATURA TEMPERATURA MODO Rx MENU’ USCITA mA USCITA mA Diagrammi di flusso sottomenù modalità Rx MENÙ MODO Rx DI BASE CONFIG.
Page 34
MENÙ MODO Rx ESTESO CONFIG. SETPOINT VALORE SETPOINT TIPO INTERVENTO TIPO INTERVENTO OSSIDANTE RIDUCENTE VALORE ISTERESI MODO INTERVENTO MODO INTERVENTO MANUALE PROPORZIONALE PORTATA MISURA MASSIMA N. IMP/MIN: RITARDO ATTIVAZ. ...
Page 35
MODO Rx MODO Rx CALIBRAZIONE TEMPERATURA CALIBRA SET1 TEMPERATURA 25°C 77°F CALIBRA SET2 MODO Rx USCITA mA IMP.SOGLIA (1) IMP. SOGLIA (2) USCITA mA (1) USCITA mA (2) ...
Diagramma di flusso modalità Cl MODO OPERATIVO MODO Cl MODO Cl MENU’ CONFIG. SETPOINT CONFIG. SETPOINT MODO Cl MENU’ CALIBRAZIONE CALIBRAZIONE MODO Cl MENU’ TEMPERATURA TEMPERATURA MODO Cl MENU’ USCITA mA USCITA mA Diagrammi di flusso sottomenù modalità Cl MODO Cl MENÙ...
Page 37
MODO Cl MENÙ CONFIG. SETPOINT ESTESO VALORE SETPOINT 0.10 Cl ppm TIPO INTERVENTO TIPO INTERVENTO DIRETTO INVERSO VALORE ISTERESI 0.10 Cl ppm MODO INTERVENTO MODO INTERVENTO MANUALE PROPORZIONALE PORTATA MISURA MASSIMA N. IMP/MIN: 0.10 Cl ppm ...
Page 38
MODO Cl MODO Cl CALIBRAZIONE TEMPERATURA CALIBRA SET1 TEMPERATURA #.## 0.00 Cl ppm 25°C 77°F CALIBRA SET2 #.## 0.40 Cl ppm MODO Cl USCITA mA IMP.SOGLIA (1) 0.00 Cl ppm IMP. SOGLIA (2) ...
Diagramma di flusso modalità ppm MODO OPERATIVO MODO ppm MODO ppm MENU’ CONFIG. SETPOINT CONFIG. SETPOINT MODO ppm MENU’ CALIBRAZIONE CALIBRAZIONE MODO ppm MENU’ TEMPERATURA TEMPERATURA MODO ppm MENU’ USCITA mA USCITA mA Diagrammi di flusso sottomenù modalità ppm MODO ppm MENÙ...
Page 40
MODO ppm MENÙ CONFIG. SETPOINT ESTESO VALORE SETPOINT 0.10 TIPO INTERVENTO TIPO INTERVENTO DIRETTO INVERSO VALORE ISTERESI 0.10 Cl ppm MODO INTERVENTO MODO INTERVENTO MANUALE PROPORZIONALE PORTATA MISURA MASSIMA N. IMP/MIN: 0.10 Cl ppm ...
Page 41
MODO ppm MODO ppm CALIBRAZIONE TEMPERATURA CALIBRA SET1 TEMPERATURA #.## 0.00 25°C 77°F CALIBRA SET2 #.## 0.40 MODO ppm USCITA mA IMP.SOGLIA (1) 0.00 IMP. SOGLIA (2) 0.40 USCITA mA (1) ...
Portata per impulso (solo versioni proporzionali ) Per un dosaggio accurato nella pompa eOne Plus è stata implementata la possibilità d’impostare sia manualmente la portata per ogni singola iniezione che automaticamente attraverso l’avvio della procedura prevista nell’apposito menù di configurazione, in questo caso, il dispositivo elettronico, effettua autonomamente i calcoli necessari per la giusta calibrazione dell’iniezione.
Temperatura (solo versioni strumentali ) E’ possibile selezionare una delle seguenti modalità funzionali: MANUALE – il valore impostato dall’utente nel menù di configurazione, rappresenta il parametro di riferimento per la compensazione del valore pH. AUTOMATICO – Il valore misurato dalla sonda rappresenta il parametro di riferimento per la compensazione del valore Ph.
DIAGRAMMA DI FLUSSO MENU IMPOSTAZIONI Alcune voci di menu sono presenti soltanto nelle versioni proporzionali o strumentali, come indicato nelle casella a fianco dei blocchi. Per accedere alle voci dei sottomenu di impostazione premere il pulsante MODO OPERATIVO IMPOSTAZIONI IMPOSTAZIONI TELEC./LIVELLO Solo su versioni...
ALLARMI La pompa dosatrice PLUS ha la possibilità di monitorare il corretto funzionamento del sistema e segnalare alcune delle situazioni di allarme che si possono verificare; nello specifico, gli allarmi che possono essere rilevati sono i seguenti: Allarme di livello ...
Qualora sia frequente l’attivazione sia frequente l’attivazione di questo allarme è consigliato l’intervento dell’operatore per la verifica delle condizioni di funzionamento dell’impianto. Allarmi valore massimo e valore minimo (solo versioni strumentali) Le pompe strumentali, mediante il dosaggio, controllano il mantenimento del valori dei parametri elettrochimici dell’acqua (pH, Redox, Cl, ppm) entro i parametri impostati in fase di programmazione della pompa.
Le funzioni UNDER-LOAD e OVER-LOAD possono essere abilitate e disabilitate agendo nel rispettivo menu di configurazione. Per impostazione di fabbrica la funzioni UNDER LOAD ed OVER LOAD sono disabilitate. Uscita servizi relè All’interno di ogni sottomenu di allarme può essere abilitato l’intervento di un relè di allarme e scelta la modalità di commutazione da NA a NC e viceversa, nei seguenti casi: ...
DIAGRAMMA DI FLUSSO MENU’ IMPOSTAZIONI ALLARMI Dal menù impostazioni IMPOSTAZIONI ALLARMI ALLARME LIVELLO ALLARME FLUSSOSTATO Solo su versioni ALLARME proporzionali IMP. CONTATORE Solo su versioni ALLARME proporzionali IMP. CONT. PPM Solo su versioni ALLARME proporzionali IMP. CONT. mlxm Solo su versioni ALLARME strumentali VALORE MAX...
Diagramma di flusso ALLARME LIVELLO ALLARME LIVELLO A. LIVELLO A. LIVELLO ABILITA DISABILITA RELE’ RELE’ DISABILITA ABILITA Diagramma di flusso ALLARME FLUSSOSTATO ALLARME FLUSSOSTATO A. FLUSSOSTATO A. FLUSSOSTATO ABILITA DISABILITA IMPULSI RIFERIM. N. IMPULSI: MAX DIFFERENZA N.
Diagramma di flu sso ALLARME MISURA MINIMA (solo versioni strumentali) ALLARME VALORE MIN A. VALORE MIN A. VALORE MIN DISABILITA ABILITA VAL. MISURA MIN Diagramma di flusso ALLARME SOVRADOSAG GIO (solo versioni strumentali) ALLARME SOVRADOSAGGIO A.SOVRADOSAGGIO A.SOVRADOSAGGIO DISABILITA ABILITA ...
Diagramma di flusso ALLARME OVERLOAD ALLARME OVERLOAD A. OVERLOAD A. OVERLOAD DISABILITA ABILITA Diagramma di flusso ALLARME UNDERLOAD ALLARME UNDERLOAD A. UNDERLOAD A. UNDERLOAD DISABILITA ABILITA ITALIANO 59...
FUNZIONE TEMPORIZZATORE PROGRAMMABILE GIORNALIERO E SETTIMANALE Il menù di impostazione TIMER è presenti nelle configurazioni VFT-T, VFT-S-T, MF-T e ST-T. La funzione menù Timer consente di gestire lo stato operativo della pompa dosatrice sopra tutte le funzioni impostate. Il timer è strutturato in modo tale che si possono avere in un giorno 16 cicli di start (Pompa Attiva) e Stop (Pompa non operativa).
Page 61
(Segue Diagramma di flusso funzione TIMER) TIMER GIORNALIERO OGNI GIORNO OGNI GIORNO 00:00 - 00:00 00:00 - 00:00 OGNI GIORNO OGNI GIORNO DISABILITA ABILITA OGNI GIORNO ACCENDI 00:00 OGNI GIORNO SPEGNI 00:00 OGNI GIORNO ACCENDI 00:00 OGNI GIORNO...
MANUTENZIONE ORDINARIA Una manutenzione ordinaria ed accurata, unitamente ad un controllo programmato, garantiscono nel tempo la conservazione ed il buon funzionamento degli impianti. Consigliamo pertanto di seguire i nostri consigli di manutenzione ordinaria e di stipulare un contratto di servizio ed assistenza programmata con un nostro Centro di Assistenza tecnica di Vostra fiducia.
ALLEGATO 1 – DISEGNI DELLA POMPA viti corpo pompa serrare con coppia di serraggio pari a 180 – 200 N*cm con una chiave esagonale da 2,5 mm SCHEDA MORSETTI Ingresso mA – (-) Ingresso mA – (+) Ingresso Contatore (-) Ingresso Contatore (+) Ingresso Livello (-) Ingresso Livello (+)
ALLEGATO 2 – VISTE ESPLOSE 1. Ghiera 2. Bussola 3. Ugello 4. O-ring 106 5. Raccordo valvola di iniezione 6. Adattatore 7. O-ring 3024/3030 8. Sfera in ceramica 9. Molla 10. Corpo valvola di iniezione Fig. 2 ITALIANO...
Page 67
(IT) DIRETTIVA "RAEE" 2002/96/CE E SUCCESSIVA MODIFICA 2003/108/CE SUI RIFIUTI DI APPARECCHIATURE ELETTRICHE ED ELETTRONICHE Il simbolo sotto riportato indica che il prodotto non può essere smaltito come normale rifiuto urbano. Le Apparecchiature Elettriche ed Elettroniche (AEE) possono contenere materiali nocivi per l'ambiente e la salute e pertanto devono essere oggetto di raccolta differenziata: smaltite quindi presso apposite discariche o riconsegnate al distributore a fronte dell'acquisto di una nuova, di tipo equivalente o facente le stesse funzioni.
Page 68
Dis ass em bl y ............................77 Wa r ran ty ............................. 77 DOSING PUMPS EONE PLUS SERIES ........................... 78 Ope rat ing p ri ncip le ..........................78 T echn i cal S pec ific atio n s ........................78 Refe r en ce S tand a rd s ........
Page 69
P ropo rti o nal pp m ( VFT -S , MF, VFT -S -T , MF - T ) ..................89 P ropo rti o nal m A ( VFT -S , MF, VFT -S -T , MF - T ) ..................89 OPERATING FUNCTIONS DIAGRAMS OF THE PLUS "PROPORTIONAL"...
Page 70
F low d iag ra m su b m en u R EM OT E CO NT ROL /L EV EL /P RO X IMIT Y ............113 F lo w d iag ra m su b m en u F L OW R AT E P E R IM PU LS E (o nly p rop o rtion al ve rs i o n s) ........113 F low d iag ra m su b m en u P PM S C AL E V AL U ES (onl y m ete ri ng v e rsio n s) ........
SAFETY STANDARDS Warnings Carefully read the warnings listed below as they provide important information regarding safe installation, use and maintenance. Store this manual carefully for future reference. PLEASE NOTE: The pump is made to perfection. Its durability, electrical and mechanical reliability will be enhanced if it is correctly used and undergoes regular maintenance.
Page 72
Assembly All Etatron DS dosing pumps are usually supplied already assembled. For greater clarity, you can consult the attachment at the bottom of the manual which illustrates an enlarged view of the pump, and all the details with its nomenclature, so that you can have a complete picture of the pump components.
DOSING PUMPS EONE PLUS SERIES Operating principle The operation of the dosing pump is provided by a membrane in PTFE (Teflon ®) mounted on the piston of an electromagnet. When the piston of the electromagnet is attracted, a pressure is produced in the pump body with an ejection of liquid from the discharge valve.
Page 74
Additional functional principles Function Description The pump controls by means of the flow-status (available on request and inserted on the pump FLOW SWITCH delivery), the actual injections delivered, signalling any anomaly, by means of the LED alarm and ALARM the switching the relevant relay (if enabled). Operational if enabled in all functional modes, the opening or closing of the contact on the level LEVEL ALARM probe, indicates the end of the additive in the tank, the pump stops and the relay switches (if...
The pump is equipped with a power supply board that regulates the power absorbed as a function of the operating pressure. (excluding the BASIC series). The following table shows the technical features of the eOne series and the corresponding flow curves: Type Flow at Max Pressure Pressure...
Materials in contact with the additive In the standard configuration the pumps of the "eOne" series are supplied with the following materials: Pump Pump Head Membrane Seals Valves Connections Pipes Casing CERAMIC PVDF PTFE TFE/P PVDF PE / PVC TFE/P INSTALLATION Introduction This section describes the steps for installing the pump, the pipes, and the electrical wiring.
Electrical connection Comply with the rules in force in the various countries with respect to the electrical installation. If the power cable is devoid of a plug, the equipment must be connected to the mains supply via a double pole isolator switch with a minimum distance between contacts of 3 mm.
Fig.5 – Bleed operation for priming Priming Function In order to facilitate the priming the pump is equipped with PRIMING function. It’s recommended to open the bleed air by-pass on pump head (for pumps with it) during priming. The air bleed nipple must always be connected with the return hose to the suction tank.
Diagram of typical system Injection fitting Injection valve Back pressure valve Pressure Gauge Relief valve Electrical power socket Additive tank Bottom filter Level probe Fig. 6 – Typical Plant Both on the flow pipe and the suction pipe avoid excessive curves in order to prevent bottlenecks in the pipe itself. In the point most suitable for the injection of the product to be dispensed, apply a 3/8"...
SPECIAL WARNINGS FOR THE METERING OF SULPHURIC ACID (MAX. 50%) In this case it is essential to bear in mind the following: replace the transparent PVC suction hose with a semi-rigid polyethylene delivery tube. remove in advance all the water present in the pump body, in fact if this is mixed with the sulphuric acid it generates a strong concentration of gas resulting in the overheating of the area causing damage to the valves and the pump body.
PLUS Proportional and Metering pump The metering pump can operate in either Proportional or control mode pH, Rx or PPM meter. At the first power on you can choose the operating configuration of the equipment. With reference to the following table, the operator can select the mode that best suits his metering needs: only some of the many programming menus will be made available, so you get a simplification and speeding up of the device commissioning.
DIAGRAM OF ELECTRICAL CONNECTIONS TO PERIPHERALS To connect the accessories and peripherals to the pump remove the front cover "1", using a flat-tip screwdriver on the two plastic screws, to access the terminal board (see Figure 9). The "3" terminal board features spring terminals (there are no screws) for quick connection of the cables: press with a small screwdriver at the "carved"...
OPERATIONAL FUNCTIONS OF THE PLUS "PROPORTIONAL" PUMP In order to facilitate the consultation of this manual, the configuration with the function described is shown in the subsection titles. Manual This configuration is present in all versions. The metering pump operates at a frequency predetermined by the user within the following range: ...
% SOLUTION Generally the additive to be dosed by the pump is part of an aqueous solution in a specified percentage. Set this value using the special arrow keys of the keyboard: 1 – 100 % ml x m SET set the value in ml x m which must be guaranteed in the plant.
OPERATING FUNCTIONS DIAGRAMS OF THE PLUS "PROPORTIONAL" PUMP Flow Diagram main menu Press the key START START/STOP to access the MENU OPERATING MODE MANUAL MODE OPERATING MODE MODH1xN OPERATING MODE 1xN(M) MODE OPERATING MODE 1÷N MODE OPERATING MODE ml x P MODE OPERATING MODE l x P MODE OPERATING MODE...
Flow Diagram 1 ÷ N mode OPERATING MODE 1÷N MODE MODE 1÷N PULSES NUM: Flow Diagram ml x P mode OPERATING MODE ml x P MODE ml x P MODE SOLUTION: 100% MODE ml x 1 ...
Flow Diagram ml x m mode OPERATING MODE MODE ml x m L/P W.METER 0.10 l SOLUTION 10.0 % PULSES/MINUTE MODE SET ml x m Flow Diagram PPM mode OPERATING MODE PPM MODE L/I METER ...
OPERATIONAL FUNCTIONS OF THE PLUS "METERING" PUMP Selecting the configurations: ST and ST-T, the metering pump is placed in the control mode and in function of the electrochemical parameter type selected (pH, RX, ppm Cl, ppm), it intervenes maintaining the correct set value. Once the instrument configuration is set, you must select one of the following operating modes: ...
BNC is connected, the remaining two cables must be inserted into the cable sleeve and connected to the ''inputs'' terminal of the pump (see Figure 10). In the Etatron list you can check the availability of the different types of sensors. The probes for chemical species are connected to the pump as shown in fig. 11 In the configuration menu of the PPM mode you can carry out the following settings: ...
OPERATING FUNCTIONS DIAGRAMS OF THE PLUS "METERING" PUMP Flow Diagram main menu Press the key START START/STOP to access the MENU OPERATING MODE MANUAL MODE OPERATING MODE pH MODE OPERATING MODE FUNCTIONS Rx MODE ACCESSORIES OPERATING MODE OPERATING MODE CI MODE TIMER OPERATING MODE OPERATING MODE...
Flow diagram PH mode OPERATING MODE pH MODE pH MODE MENU SETPOINT SETUP SETPOINT SETUP pH MODE MENU CALIBRATION CALIBRATION pH MODE MENU TEMPERATURE TEMPERATURE pH MODE MENU mA OUTPUT OUTPUT mA Flow diagrams pH mode submenu BASIC pH MODE MENU SETPOINT SETUP ...
Page 94
FULL pH MODE MENU SETPOINT SETUP SETPOINT VALUE 7.20 OPERATION TYPE OPERATION TYPE ACID ALKALINE HYSTERESIS VALUE 0.10 OPERATION MODE OPERATION MODE PROPORTIONAL MANUAL CAPACITY MAX MEASURE PULSES/MIN:300 START DELAY ...
Page 95
pH MODE pH MODE CALIBRATION TEMPERATURE CALIBR. SET1 TEMPERATURE 7.00 25°C 77°F CALIBR. SET2 4.00 pH MODE mA OUTPUT SET THOLD (1) 4.00 SET THOLD (2) 7.00 mA OUTPUT (1) ...
Flow diagram RX mode OPERATING MODE Rx MODE Rx MODE MENU SETPOINT SETUP SETPOINT SETUP Rx MODE MENU CALIBRATION CALIBRATION Rx MODE MENU TEMPERATURE TEMPERATURE Rx MODE MENU mA OUTPUT mA OUTPUT Flow diagrams RX mode submenu BASIC Rx MODE MENU SETPOINT SETUP ...
Page 97
Rx MODE FULL SETPOINT SETUP MENU SETPOINT VALUE 650.0 OPERATION TYPE OPERATION TYPE OXIDANT REDUCING HYSTERESIS VALUE OPERATION MODE OPERATION MODE MANUAL PROPORTIONAL MAX MEASURE CAPACITY PULSES/MIN:300 START DELAY ...
Page 98
Rx MODE Rx MODE CALIBRATION TEMPERATURE CALIBR. SET1 TEMPERATURE 0.00 25°C 77°F CALIBR. SET2 650.0 Rx MODE mA OUTPUT SET THOLD (1) 0.00 SET THOLD (2) 650.0 mA OUTPUT (1) ...
Flow diagram C L mode OPERATING MODE CI MODE CI MODE MENU SETPOINT SETUP SETPOINT SETUP CI MODE MENU CALIBRATION CALIBRATION CI MODE MENU TEMPERATURE TEMPERATURE CI MODE MENU mA OUTPUT mA OUTPUT Flow diagrams CL mode submenu BASIC CI MODE MENU SETPOINT SETUP ...
Page 100
CI MODE FULL SETPOINT SETUP MENU SETPOINT VALUE 0.10 Clppm OPERATION TYPE OPERATION TYPE DIRECT REVERSE HYSTERESIS VALUE 0.10 Cl ppm OPERATION MODE OPERATION MODE MANUAL PROPORTIONAL CAPACITY MAX MEASURE PULSE/MIN: 0.10 Cl ppm ...
Page 101
CI MODE CI MODE CALIBRATION TEMPERATURE CALIBR. SET1 TEMPERATURE 0.00 Cl ppm 25°C 77°F CALIBR. SET2 0.40 Cl ppm CI MODE mA OUTPUT SET THOLD (1) 0.00 Clppm SET THOLD (2) ...
Flow diagram ppm mode OPERATING MODE ppm MODE ppm MODE MENU SETPOINT SETUP SETPOINT SETUP ppm MODE MENU CALIBRATION CALIBRATION ppm MODE MENU TEMPERATURE TEMPERATURE ppm MODE MENU mA OUTPUT mA OUTPUT Flow diagrams ppm mode submenu ppm MODE BASIC SETPOINT SETUP MENU ...
Page 103
ppm MODE FULL SETPOINT SETUP MENU SETPOINT VALUE 0.10 OPERATION TYPE OPERATION TYPE DIRECT REVERSE HYSTERESIS VALUE 0.10 Cl ppm OPERATION TYPE OPERATION TYPE MANUAL PROPORTIONAL CAPACITY MAX MEASURE PULSE/MIN: 0.10 ...
Page 104
ppm MODE ppm MODE CALIBRATION TEMPERATURE CALIBR. SET1 TEMPERATURE 0.00 25°C 77°F CALIBR. SET2 0.40 ppm MODE mA OUTPUT SET THOLD (1) 0.00 SET THOLD (2) 0.40 mA OUTPUT (1) ...
Flow rate per impulse (proportional versions only) For accurate metering in the eOne Plus pump the option to both manually and automatically set the flow rate for each injection has been implemented by starting the procedure laid down in the appropriate configuration menu, in this case, the electronic device, performs independently the necessary calculations for the proper calibration of the injection.
Temperature ( Instrument versions only) It is possible to select one of the following operational modes: MANUAL – the value set in the configuration menu by the user, is the reference parameter for the compensation of the pH value. ...
FLOW DIAGRAM SETTINGS MENU Some menu items are only present in the proportional or control versions, as shown in the box next to the blocks. To access the items of the Setting Submenus press the button OPERATING MODE SETTINGS SETTINGS REMOTE/LEV/PROXI Only on...
Flow diagram submenu PPM SCALE VALUES (only metering versions) SETTINGS PPM RANGE VALUES PPM RANGE VALUES PPM RANGE VALUES 0 2 0 200 Flow diagram sub menu MAXIMUM FREQUENCY SETTINGS MAX FREQUENCY MAX FREQUENCY PULSES/MIN: Flow diagram alarm settings submenu See Alarms Chapter ENGLISH...
ALARMS The PLUS Metering pump has the ability to monitor the proper functioning of the system and signal some alarm situations that may occur. It can specifically detect the following alarms: Level alarm Flow switch alarm Meter impulse alarm that intervenes in the 1xN (M) function - only proportional versions ...
If the activation of this alarm is frequent it is recommended that the operator checks the operating conditions of the plant. Maximum value and minimum value alarms (Instrument versions only) The control pumps, by the metering, control the maintenance of the values of the electrochemical parameters of the water (pH, Redox, Cl, ppm) within the parameters set during the programming of the pump.
Relay services output Within each alarm submenu an alarm relay can be enabled, and the choice of switching mode from NO to NC and vice versa, in the following cases: Level alarm Flow switch alarm Meter impulse alarm that intervenes in the 1xN (M) function (only proportional versions) ...
FLOW DIAGRAM ALARM SETTINGS MENU From the settings menu SETTINGS ALARMS LEVEL ALARM FLOW METER ALARM Only on W.M. PULSE proportional versions ALARM Only on PPM W.M.PULSE proportional versions ALARM Only on mlxm W.M.PULSE proportional versions ALARM Only on MAX VALUE metering versions ALARM Only on...
Flow diagram LEVEL ALAR M LEVEL ALARM LEVEL A. LEVEL A. ENABLE DISABLE RELAY RELAY DISABLE ENABLE Flow diagram FLOW METER ALARM FLOW METER ALARM FLOW METER A. FLOW METER A. ENABLE DISABLE REFERENCE PULSES PULSES NUM:100 ...
Flow diagram ml x m WATER METER PULSE ALARM (proportional versions only) mlxm W.M. PULSE ALARM mlxm W.M. PULSE mlxm W.M. PULSE DISABLE ENABLE PUMP PUMP ENABLE DISABLE RELAY RELAY DISABLE ENABLE Flow diagram MAX IMUM MEASURE ALARM (metering versions only) MAX VALUE ALARM MAX VALUE A.
Flow diagram MINIMUM MEASUREMENT ALARMS (metering versions only) MIN VALUE ALARM MIN VALUE A. MIN VALUE A DISABLE ENABLE MEASURE MIN VAL Flow diagram OVERDOSE ALARM ( metering versions only) OVERDOSING ALARM OVERDOSE A. OVERDOSE A. DISABLE ENABLE ...
Flow diagram OVERLO AD ALARM OVERLOAD ALARM OVERLOAD A. OVERLOAD A. DISABLE ENABLE Flow diagram UNDERLOAD ALARM UNDERLOAD ALARM UNDERLOAD A. UNDERLOAD A. DISABLE ENABLE ENGLISH 127...
PROGRAMMABLE TIMER FUNCTION DAILY AND WEEKLY The TIMER settings menu is present in the configurations VFT-T VFT-ST, MF-T and ST-T. The Timer menu function allows you to manage the operating status of the metering pump over all the set functions. The timer is structured in such a way that you can have 16 start cycles in a day (Pump On) and Stop (Pump not operating).
ROUTINE MAINTENANCE A thorough and routine maintenance, together with a scheduled inspection, ensures long preservation and good functioning of the systems We therefore recommend you follow our routine maintenance advice and to enter into a programmed service and assistance contract with one of our trusted Technical Support Centres. At least every 6 months check the operation of the pump.
ANNEX 1 - PUMP DRAWINGS screws pump body tighten with a torque of 180 - 200 N * cm with a 2.5 mm hex wrench TERMINALS DATA SHEET Input mA – (-) Input mA – (+) Meter Input (-) Meter Input (+) Level Input (-) Level Input (+) Flow Switch Input (-)
Page 130
(IT) DIRETTIVA "RAEE" 2002/96/CE E SUCCESSIVA MODIFICA 2003/108/CE SUI RIFIUTI DI APPARECCHIATURE ELETTRICHE ED ELETTRONICHE Il simbolo sotto riportato indica che il prodotto non può essere smaltito come normale rifiuto urbano. Le Apparecchiature Elettriche ed Elettroniche (AEE) possono contenere materiali nocivi per l'ambiente e la salute e pertanto devono essere oggetto di raccolta differenziata: smaltite quindi presso apposite discariche o riconsegnate al distributore a fronte dell'acquisto di una nuova, di tipo equivalente o facente le stesse funzioni.
Page 131
Dém ont age ............................145 Ga rant ie ............................145 POMPES DOSEUSES SERIE EONE PLUS ........................146 P rin cipe de fon cti o nnem ent ....................... 146 Ca ra c té ri stiqu es t echni q ues ......................146 No rm es de r éfé...
Page 132
P ropo rti o nnel le m A (V FT -S, MF, VFT - S-T, MF - T ) .................. 156 DIAGRAMME DES FONCTIONS DE LA POMPE PLUS “PROPORTIONNELLE” ............157 Diag r am m e d e f lu x m enu prin cip al ..................... 157 Diag r am m e d e f lu x en m o de m anu el ....................
Diag r am m e d u fl u x sous - m enu D ÉB IT P AR IM P UL S IO N (s eulem ent p rop o r ti onnell es) ......180 Diag r am m e d u fl u x sous - m enu V AL EU R S D' É C H EL LE p pm (s eule m ent inst r um en tal es) ......181 Diag r am m e du fl u x sous - m enu F R ÉQ U EN C E MA XI MAL E ..............
Mises en garde Lire attentivement les mises en garde énumérées ci-après, car elles fournissent des indications importantes concernant la sécurité d'installation, d'utilisation et de maintenance. Il faut conserver soigneusement ce manuel pour toute autre éventuelle consultation. NOTA BENE : La pompe est construite dans les règles de l'art. Sa durée, sa fiabilité électrique et mécanique seront meilleures si cette dernière est utilisée correctement et avec une maintenance régulière.
(gants, lunettes, combinaisons, etc.). Montage Toutes les pompes doseuses Etatron DS produites, sont normalement fournies assemblées. Pour plus d'informations, voir l'annexe en bas du manuel où sont reportées sur les vues éclatées des pompes, toutes les pièces avec la nomenclature relative, de manière à...
POMPES DOSEUSES SERIE EONE PLUS Principe de fonctionnement Le fonctionnement de la pompe doseuse est assuré par une membrane en PTFE (téflon®) montée sur le piston d'un électro-aimant. Lorsque le piston de l'électro-aimant est attiré, une pression se produit dans le corps pompe avec une expulsion du liquide par la vanne de refoulement.
Principales fonctions supplémentaires : Fonction Description La pompe contrôle, au moyen d'un débitmètre (disponible sur demande et inséré sur le refoulement ALARME de la pompe), les injections qui sont effectivement produites en signalant les éventuelles anomalies, DÉBITMÈTRE par éclairage d'une led d'alarme et la commutation du relais spécifique (si activé). Si elle est activée, elle intervient dans tous les modes de fonctionnement, l'ouverture ou la ALARME NIVEAU fermeture du contact se trouvant sur la sonde de niveau, indique la fin de l'additif se trouvant dans...
La pompe est équipée d'une carte d'alimentation qui règle la puissance absorbée en fonction de la contre pression de fonctionnement. (exclue dans la série BASIC). Les caractéristiques techniques de la série eOne et les courbes correspondantes de débit sont reportées dans le tableau suivant : Type Débit à...
Matériaux en contact avec l'additif Dans la configuration standard les pompes de la série “eOne” sont fournies avec les matériaux suivants : Tëte de la Joints Corps Membrane Vannes Raccords Tuyaux pompe d'étanchéité pompe CÉRAMIQU PVDF PTFE TFE/P PVDF PE / PVC TFE/P INSTALLATION Introduction...
Branchement électrique Il faut respecter les normes en vigueur dans les différents pays, quant à l'installation électrique. Si le câble d'alimentation est sans fiche électrique, l'appareil doit être branché au secteur d'alimentation par un interrupteur omnipolaire disjoncteur ayant une distance minimale entre les contacts de 3 mm Avant d'accéder aux dispositifs de branchement, tous les circuits d'alimentation doivent être coupés (fig.
Fig.5 - Actionnement purge pour amorçage Schéma d'une installation type Raccord d'injection Vanne d'injection Vanne de contre-pression Manomètre Vanne de trop-plein Prise pour l'alimentation électrique Réservoir additif Filtre de pied Sonde de niveau Fig. 6 - Installation type Tant sur le tuyau de refoulement que sur celui d'aspiration, il faut éviter les coudes excessifs afin de ne pas provoquer des étranglements sur le tuyau.
Équipement En équipement avec la pompe : 4 m de tube d'aspiration en PVC transparent flexible 2 m de tube de refoulement en polyéthylène semi-rigide opaque 1 vanne d'injection 3/8” – ½” BSP 1 filtre de pied ...
Pompe Proportionnelle et instrumentale PLUS La pompe doseuse peut fonctionner tant en mode proportionnel qu'en mode instrumental mesureur de pH, Rx ou PPM. Lors de la première mise en marche, il est possible de choisir la configuration de fonctionnement de l'appareil. En se référant au tableau suivant, l'opérateur peut sélectionner le mode le mieux adapté...
SCHÉMA DES BRANCHEMENTS ÉLECTRIQUES AUX PÉRIPHÉRIQUES Pour connecter les accessoires et les périphériques à la pompe, il faut déposer le couvercle frontal “1” en intervenant avec un tournevis plat sur les deux vis en plastique, pour accéder au bornier de connexion (voir fig. 9) Le bornier “3”...
FONCTIONS DE LA POMPE PLUS “PROPORTIONNELLE” Afin de faciliter la consultation du présent manuel, dans les titres des sous-paragraphes, il est indiqué la configuration comprenant la fonction décrite. Manuelle Cette configuration est présente dans toutes les versions La pompe doseuse fonctionne à une fréquence préréglée par l'utilisateur et comprise dans les plages suivantes : ...
DIAGRAMME DES FONCTIONS DE LA POMPE PLUS “PROPORTIONNELLE” Diagramme flux menu principal Appuyer sur la touche DÉBUT MARCHE/ARRÊT pour entrer dans le MENU MODALITÉ MODE MANUEL MODALITÉ MODE 1xN MODALITÉ MODE 1xN(M) MODALITÉ MODE 1÷N MODALITÉ MODE ml x I MODALITÉ...
Diagramme de flux en mode manuel MODALITÉ MODE MANUEL MODE MANUEL MODE MANUEL MODE MANUEL COUPS/MINUTE COUPS/HEURE COUPS/JOUR COUPS/MINUTE N. COUPS : COUPS/HEURE N. COUPS : COUPS/JOUR N. COUPS : Diagramme de flux en mode 1xN MODALITÉ...
Diagramme de flux en mode 1 ÷ N MODALITÉ MODE 1÷N MODE 1÷N N. COUPS : Diagramme de flux en mode ml x Imp MODALITÉ MODE ml x I MODE ml x I SOLUTION : 100% MODE ml x Imp ...
Diagramme de flux en mode ml x m MODALITÉ MODE ml x m L/I COMPTEUR 0.10 l SOLUTION 10.0 % IMPULSIONS/MINUT E MODE VOLUME ml x m Diagramme de flux en mode PPM MODALITÉ MODE PPM ...
FONCTION DE LA POMPE PLUS “INSTRUMENTALE” En sélectionnant les configurations : ST et ST-T, la pompe doseuse se met en mode instrumental et en fonction du type de paramètre électrochimique sélectionné (pH, RX, Cl ppm, ppm), elle intervient en maintenant la valeur configurée. Après avoir défini la configuration instrumentale, il faut sélectionner l'un des modes de fonctionnement suivants : ...
BNC connecté, les deux câbles restant doivent être insérés dans le presse-étoupe et connectés au bornier “entrées” dans la pompe (voir fig. 10) Dans le tarif Etatron, il est possible de contrôler la disponibilité des différents types de capteurs. Les sondes pour les types chimiques se connectent à la pompe comme indiqué sur la fig. 11 Dans le menu de configuration du mode PPM, il est possible d'effectuer les programmations suivantes : ...
DIAGRAMMES DES FONCTIONS DE LA POMPE PLUS “INSTRUMENTALE” Diagramme flux menu principal Appuyer sur la touche DÉBUT MARCHE/ARRÊT pour entrer dans le MENU MODALITÉ MODE MANUEL MODALITÉ MODE pH MODALITÉ FONCTIONS MODE RX ACCESSOIRES MODALITÉ MODALITÉ MODE Cl TEMPORISATEUR MODALITÉ MODALITÉ...
Diagramme du flux en mode PH MODALITÉ MODE pH MODE pH MENU CONFIG. POINT CONSIGNE POINT CONSIGNE MODE pH MENU CALIBRAGE CALIBRAGE MODE pH MENU TEMPÉRATURE TEMPÉRATURE MODE pH MENU SORTIE mA SORTIE mA Diagramme du flux sous -menu en mode PH MENU MODE pH SIMPLIFIÉ...
Page 156
MENU MODE pH COMPLET POINT CONSIGNE VAL. CONSIGNE 7.20 PRODUIT DOSE PRODUIT DOSE ACIDE ALCALIN VAL. HYSTÉRÉSIS 0.10 MODE MODE TOUT OU RIEN PROPORTIONNEL DÉBIT MESURE MAXIMALE N.COUPS/MIN: RETARD ACTIV. ...
Diagramme du flux en mode Rx MODALITÉ MODE Rx MODE Rx MENU CONFIG. POINT CONSIGNE POINT CONSIGNE MODE Rx MENU CALIBRAGE CALIBRAGE MODE Rx MENU TEMPÉRATURE TEMPÉRATURE MODE Rx MENU SORTIE mA SORTIE mA Diagramme du flux sous -menu en mode Rx MENU MODE Rx SIMPLIFIÉ...
Page 159
MENU MODE Rx COMPLET POINT CONSIGNE VAL. CONSIGNE 650.0 PRODUIT DOSE PRODUIT DOSE OXYDANT RÉDUCTEUR VAL. HYSTÉRÉSIS MODE MODE TOUT OU RIEN PROPORTIONNEL DÉBIT MESURE MAXIMALE COUPS/MIN: RETARD ACTIV. ...
Page 160
MODE Rx MODE Rx CALIBRAGE TEMPÉRATURE CALIBRAGE 1 TEMPÉRATURE 25°C 77°F CALIBRAGE 2 650mV MODE Rx SORTIE mA SEUIL (1) SEUIL (2) mA a VALEUR (1) mA a VALEUR (2) ...
Diagramme du flux en mode Cl MODALITÉ MODE Cl MODE Cl MENU CONFIG. POINT CONSIGNE POINT CONSIGNE MODE Cl MENU CALIBRAGE CALIBRAGE MODE Cl MENU TEMPÉRATURE TEMPÉRATURE MODE Cl MENU SORTIE mA SORTIE mA Diagramme du flux sous -menu en mode Cl MODE Cl MENU POINT CONSIGNE...
Page 162
MODE Cl MENU POINT CONSIGNE COMPLET VAL. CONSIGNE 0.10 Cl ppm PRODUIT DOSE PRODUIT DOSE DIRECT INVERSÉ VAL. HYSTÉRÉSIS 0.10 Cl ppm MODE MODE TOUT OU RIEN PROPORTIONNEL DÉBIT MESURE MAXIMALE COUPS/MIN: 0.10 Cl ppm ...
Diagramme du flux en mode ppm MODALITÉ MODE ppm MODE ppm MENU CONFIG. POINT CONSIGNE POINT CONSIGNE MODE ppm MENU CALIBRAGE CALIBRAGE MODE ppm MENU TEMPÉRATURE TEMPÉRATURE MODE ppm MENU SORTIE mA SORTIE mA Diagramme du flux sous -menu en mode ppm MODE ppm MENU POINT CONSIGNE...
Page 165
MODE ppm MENU POINT CONSIGNE COMPLET VAL. CONSIGNE 0.10 TYPE DE DOSAGE TYPE DE DOSAGE DIRECT INVERSÉ VAL. HYSTÉRÉSIS 0.10 Cl ppm MODE MODE TOUT OU RIEN PROPORTIONNEL DÉBIT MESURE MAXIMALE COUPS/MIN: 0.10 Cl ppm ...
Débit par impulsion (seulement versions proportionnelles) Pour un dosage précis dans la pompe eOne Plus, il a été implémentée la possibilité de configurer, tant manuellement qu'automatiquement, le débit pour chaque injection par le lancement de la procédure prévue dans le menu spécifique de configuration et dans ce cas le dispositif électronique effectue automatiquement les calculs nécessaires pour le réglage...
Température (seulement versions instrumentales) Il est possible de sélectionner l'un des modes de fonctionnement suivant : MANUEL - La valeur configurée par l'utilisateur dans le menu de configuration, représente le paramètre de référence pour la compensation de la valeur pH. ...
DIAGRAMME DU FLUX MENU CONFIGURATIONS Certaines rubriques du menu ne sont présentent que dans les versions proportionnelles ou instrumentales, comme indiqué dans les cases à côté des blocs. Pour accéder aux rubriques des sous-menus de configuration, il faut appuyer sur le ...
Diagramme du flux sous -menu VALEURS D'ÉCHELLE ppm (seulement instrumentales ) RÉGLAGES VAL. ÉCHELLE ppm VAL. D'ÉCHELLE VAL. D'ÉCHELLE 0 2 0 20 Diagramme du flux sous -menu FRÉQUENCE MAX IMALE RÉGLAGES FRÉQUENCE MAX FRÉQUENCE MAX N.COUPS/MIN: Diagramme du flux sous -menu des configurations des alarmes Voir chapitre consacré...
Diagramme du flux sous -menu MOT DE PASSE RÉGLAGES MOT DE PASSE MOT DE PASSE MOT DE PASSE DÉSACTIVER ACTIVER MOT DE PASSE 0000 MOT DE PASSE 0000 MOT DE PASSE 0000 MOT DE PASSE ...
Diagramme du flux sous -menu MODE MENU (seulement instrumentales) RÉGLAGES MODE MENU MODE MENU MODE MENU SIMPLIFIÉ COMPLET RET. SORTIE MENU 02:00 (min:sec) Diagramme du flux sous -menu RETARD DE DÉMARRAG E (seulement instrumentales) RÉGLAGES RETARD ACTIV. ...
Diagramme du flux sous -menu RÉINITIALISATION RÉGLAGES RÉINITIALISATION UNDERLOAD A. PULSE A. RÉINITIALISATION RÉINITIALISATION PARTIELLE TOTALE DÉBUT SETUP SETUP FW08 ST-T FW01 MARCHE MARCHE ARRÊT ARRÊT DÉBUT DÉBUT FRANÇAIS 185...
ALARMES La pompe doseuse PLUS a la possibilité de surveiller le bon fonctionnement du système et de signaler certaines situations d'alarme qui peuvent se produire ; dans le cas spécifique, les alarmes qui peuvent être relevées sont les suivantes Alarme de niveau ...
L'alarme s'active si le nombre des injections mémorisées et non fournies dépasse la valeur 4*N où N est le nombre d'injections à fournir pour chaque impulsion du compteur. Le nombre des injections encore à fournir est visualisé sur l'afficheur de la pompe. Le choix du facteur 4 représente une méthode simple pour éviter que d'éventuels phénomènes transitoires puissent provoquer de fausses alarmes.
et le relais est activé. Même dans ce cas l'arrêt de la pompe s'effectue après 20 injections après le début de la situation. Dans particulier conditions de pression peut vérifier la conditions de SUPRESSION aussi en présence d’air dans le tête de pompe on conseille de contrôler le correct fonctionnement de la pompe.
DIAGRAMME DU FLUX SOUS-MENU DES CONFIGURATIONS DES ALARMES Par le menu des configurations RÉGLAGES ALARMES ALARME DE NIVEAU ALARME DÉBITMÈTRE Seulement sur les ALARME versions IMP. COMPTEUR proportionnelles Seulement sur les ALARME versions IMP. COMPT. PPM proportionnelles Seulement sur les ALARME versions IMP.
Diagramme du flux ALARME NIVEAU ALARME NIVEAU ALR. DE NIVEAU ALR. DE NIVEAU ACTIVER DÉSACTIVER RELAIS RELAIS DÉSACTIVER ACTIVER Diagramme du flux ALARME DÉBITMÈTRE ALARME DÉBITMÈTRE ALR. DÉBITMÈTRE ALR. DÉBITMÈTRE DÉSACTIVER ACTIVER COUPS RÉFÉRENCE N. COUPS : ...
Diagramme du flux ALARME ml x m (seulement versions proportionnelles) ALARME I. COMPT. mlxm A. COMPT. mlxm A. COMPT. mlxm DÉSACTIVER ACTIVER POMPE POMPE ACTIVER DÉSACTIVER RELAIS RELAIS DÉSACTIVER ACTIVER Diagramme du flux ALARME MESURE MAXIMALE (seulement versions instrumentales) ALARME VALEUR MAX ALR.
FONCTION TEMPORISATEUR PROGRAMMABLE QUOTIDIEN ET HEBDOMADAIRE Le menu de configuration TEMPORISATEUR se trouve dans les configurations VFT-T, VFT-S-T, MF-T et ST-T. La fonction menu temporisateur permet de gérer la condition de fonctionnement de la pompe doseuse sur toutes les fonctions configurées.
Page 186
(suite du diagramme du flux fonction TEMPORISATEUR) TEMPORISATEUR QUOTIDIEN CHAQUE JOUR CHAQUE JOUR 00:00 - 00:00 00:00 - 00:00 CHAQUE JOUR #01 CHAQUE JOUR #01 DÉSACTIVER ACTIVER CHAQUE JOUR #01 ACTIVER 00:00 CHAQUE JOUR #01 ACTIVER 00:00 CHAQUE JOUR #01 ...
MAINTENANCE ORDINAIRE Une maintenance ordinaire et minutieuse, alliée à un contrôle programmé, assurent dans le temps la conservation et le bon fonctionnement des installations. Il est donc conseillé de suivre nos conseils de maintenance ordinaire et de stipuler un contrat de service et d'assistance programmée avec l'un de nos centres d'assistance technique. Contrôler au moins une fois tous les 6 mois le fonctionnement de la pompe.
ANNEXE 1 - PLANS DE LA POMPE vis corps pompe serrer avec un couple de serrage de 180 – 200 N*cm à l'aide d'une clé à six pans de 2,5 mm CARTE BORNES Entrée mA - (-) Entrée mA - (+) Entrée compteur (-) Entrée compteur (+) Entrée niveau (-)