Electrical installation
Power supply
Max. nominal output
Fuse protection
RCD
Pre-installation
> Installing a permanent power supply line:
Pre-connect a separate fuse and
residual current operating device (RCD)
Pre-connect an all-pole separating main switch
Allow the supply line to protrude by 3,000 mm
56
Connecting the sauna (Diagram 56)
NOTE! Avoiding any malfunctions!
> Do not fasten the cables together with cable ties.
I
Connect the supply line to the controls.
57
Checking the functions (Diagram 57)
Operating the stove without sauna stones can lead
to unacceptably high temperatures.
> Only operate the stove with sauna stones.
> Place the magnet on the door contact.
> Check the functions.
> Remove the magnet.
58
Installing the cable (Diagram 58)
> Do not install the main supply lines parallel to the
control cables.
3N ~ 380 – 415 V 50/60 Hz
6.6 kW
I
= 16 A
N
I
30 mA
N
I
7