Conductivity/ Tds/ Salinity/ Resistivity Settings; Dissolved Ogygen Setup; Do (%) Settings - Page - EIJKELKAMP 18.52.01 Manuel D'instructions

Masquer les pouces Voir aussi pour 18.52.01:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Parameter
Pure water Coeff.
Lnr Temp Coeff.
Normalization
Temp
Cell Constant
Calibration due
Calibration points
Calibration mode
2.7.2
Conductivity/ TDS/ Salinity/ Resistivity Settings - Page 2
1.
Press
or
to enable / disable alarms.
2.
Press ENTER to save or F3 to go to next step without saving
3.
Press
or
to set High alarm
4.
Press ENTER to save or F3 to go to next step without saving.
5.
Press
or
to set Low alarm
6.
Press ENTER to save or F3 to go to next page without saving.
Parameter
Description
Alarm Set
ENABLE – Screen shows HI or LO alarm indicators when the
Point
reading is above 'HI alarm value' or below 'LO alarm value'
DISABLE – HI and LO alarms are not shown.
Hi pH
Hi alarm value ('ALARM' must be enabled)
Lo pH
Lo alarm value ('ALARM' must be enabled)
2.8

Dissolved Ogygen Setup

Available on 18.52.01 meter only.
2.8.1

DO (%) Settings - Page 1

1.
Follow step 1 – 6 from paragraph 2.2.1. to enter setup menu
2.
Press
or
to select offset %.
3.
Press ENTER to save or F3 to go to next step without saving.
4.
Press
or
to select Due days.
5.
Press ENTER to save or F3 to go to next step without saving.
6.
Press
or
to select Barometric Pressure units
7.
Press ENTER to save or F3 to go to next step without saving.
8.
Press
or
to adjust Barometric Pressure value
9.
Press ENTER to save or F3 to go to next step without saving.
10. Press
or
to enable / disable Barometric Pressure Compensation.
11. Press ENTER to save or F3 to go to next page without saving.
Parameter
Offset Cal
Calibration due
Select Pressure Unit
Measured Pressure
Adjusted Pressure
Pressure
Compensation
Description
ENABLE': Pure water compensation will apply automatically below 2 µS and
switch back to linear compensation above 2 µS.
DISABLE': Lnr Temp Coefficient applies throughout the measurement.
Enter temperature coefficient to measure temperature corrected conductivity
Used with the temperature coefficient to calculate a temperature corrected
measurement.
Available: 0.1 to 10
Enter # of days for calibration alarm. Indicator appears after due days are
passed from last calibration date. Range: 0 - 30 days
Single - 1 calibrated value is used for all 5 ranges.
Multi - Calibrate one point in each of the measuring ranges (up to 5 points.)
AUTO- automatically detects & verifies known calibration standards solutions.
Manual- enables manual input of calibration standards in each specific range.
Function
To adjust % saturation offset calibration
Enter # of days for calibration alarm. Indicator appears after due days are
passed from last calibration date. Range: 0 - 30 days
Select barometric pressure units: mmHg or kPa
Barometric pressure measured (not adjustable)
Adjustable value.
ENABLE – Barometric pressure compensation is on.
DISABLE – Compensation is off. (In mg/L or ppm mode always on).
16
Conductivity Settings
Page 2