Thermometer/alarm instructions (cont'd):

Function of Controls:

MODE/RESET Key: Press ONCE to reset Max/Min temperature record. When the unit
is sounding an alarm, press ONCE to turn off the beeping sound.
HIGH/LOW Key: Press ONCE to display high alarm setting. Press TWICE to display
low alarm setting. Press THREE TIMES to display current temperature reading.
ALERT ON/OFF Key: When the unit is sounding an alarm, press ONCE to turn off.
However, the High-Alarm or Low-Alarm will still flash until the temperature goes
back to normal or the Alarm function is turned off.
Programming the Alarms:
The thermometer displays the internal temperature of the unit being monitored, as
well as the maximum and minimum temperatures reached. The maximum and
minimum readings reflect the highest and lowest temperatures since the battery was
inserted or since the MODE/RESET key was last pressed. If the temperature rises
above or falls below the set temperature range, the alarm will sound. By default, the
high alarm temperature setting is 8°C (46.4°F) and the low alarm temperature setting
is 2°C (35.6°F). To reset these limits, follow these instructions:
High Alarm Temperature Setting: Press the HIGH/LOW key ONCE, then press
MODE/RESET to enter the High Alarm temperature setting mode. Use the Up and
Down arrows to adjust the temperature accordingly. Press MODE/RESET once
again to confirm the setting.
Low Alarm Temperature Setting: Press the HIGH/LOW key TWICE, then press
MODE/RESET to enter the Low Alarm temperature setting mode. Use the Up and
Down arrows to adjust the temperature accordingly. Press MODE/RESET ONCE to
confirm the setting.
By default, the low and high alarms should be audible. To turn alarms on/off:
Audible High Alarm Setting: To make sure the high alarm is audible, press HIGH/LOW
key ONCE (to activate HI-SET on the screen). Then press the ALERT ON/OFF key
ONCE to activate the HIGH-ALARM beeping sound. Press again to deactivate.
Audible Low Alarm Setting: To make sure that the low temperature alarm is audible,
press the HIGH/LOW key TWICE to activate LOW-SET on the screen. Then press
the ALERT ON/OFF key ONCE to activate the LOW-ALARM beeping sound. Press
again to deactivate.
NOTE: For an activated high alarm and low alarm
buzzer, the display should indicate HI-ALARM
and LO-ALARM as shown here.
More details about the features and usage of the Traceable Thermometer/Alarm can
be found in the User Manual accompanying the unit.