Add new operators to the list of operators in the module.
Delete the list in the module and create a new list.
Show the peripheral number assigned to the operator; this number is very
important when multiple operators are controlled by one control panel.
☞ The value is "1" in the factory settings of CAME control panels.
Edit the configuration of the chosen operator.
Remove the selected operator from the list.
Delete all operators from the list.
Transfer the configuration into the module
Once you have configured the parameters required by the type of connectivity choice
you've made, from the
[File]
menu select item [Save], this generates two files.
These two generated files must be saved at the root level to a USB flash-drive.
Check that there are no other configuration files at the USB flash-drive's initial
(root) level.
Check that the CONNECT GW gateway module is powered OFF, and that all
connectors are unplugged from their sockets.
1. Fit the flash-drive, on which you previously saved the configuaration files, into the
USB port on the CONNECT GW module and then power ON again.
2. The red DL4 LED lights up and then the red DL3 LED flashes.
3. The red DL3 LED flashed quickly for some seconds while settings and
configurations are being processed.
4. When the red DL3 LED switches off, this means the configuration is now saved in
the module.
5. Power OFF the module.
6. Remove the USB unit and possibly refit the USB-LAN or USB-Wi-Fi converter.
7. Power ON the module; the module is ready to function.